S3C2440A RISC MICROPROCESSOR     USB DEVICE 
  13-13 
END POINT0 CONTROL STATUS REGISTER (EP0_CSR) 
This register has the control and status bits for Endpoint 0. Since a control transaction is involved with both IN and 
OUT tokens, there is only one CSR register, mapped to the IN CSR1 register. (Share IN1_CSR and can access by 
writing index register “0” and read/write IN1_CSR) 
Register Address  R/W  Description  Reset Value
EP0_CSR 0x52000184(L) 
0x52000187(B) 
R/W 
(byte) 
Endpoint 0 status register  0x00 
EP0_CSR Bit MCU USB  Description  Initial 
State
SERVICED_SE
TUP_END 
[7]  W  CLEAR  The MCU should write a "1" to this bit to clear 
SETUP_END. 
0 
SERVICED_OU
T_PKT_RDY 
[6]  W  CLEAR  The MCU should write a "1" to this bit to clear 
OUT_PKT_RDY. 
0 
SEND_STALL  [5]  R/W  CLEAR  MCU should write a "1" to this bit at the same time it clears 
OUT_PKT_RDY, if it decodes an invalid token. 
0 = Finish the STALL condition 
1 = The USB issues a STALL and shake to the 
 current control transfer. 
0 
SETUP_END  [4]  R  SET  Set by the USB when a control transfer ends before 
DATA_END is set. 
When the USB sets this bit, an interrupt is generated to 
the MCU. 
When such a condition occurs, the USB flushes the FIFO 
and invalidates MCU access to the FIFO. 
0 
DATA_END  [3]  SET  CLEAR  Set by the MCU on the conditions below: 
1. After loading the last packet of data into the FIFO, at the 
same time IN_PKT_RDY is set. 
2. While it clears OUT_PKT_RDY after unloading the last 
packet of data. 
3. For a zero length data phase. 
0 
SENT_STALL [2] CLE
AR 
SET  Set by the USB if a control transaction is stopped due to a 
protocol violation. An interrupt is generated when this bit is 
set. The MCU should write "0" to clear this bit. 
0 
IN_PKT_RDY  [1]  SET  CLEAR  Set by the MCU after writing a packet of data into EP0 
FIFO. The USB clears this bit once the packet has been 
successfully sent to the host. An interrupt is generated 
when the USB clears this bit, so as the MCU to load the 
next packet. For a zero length data phase, the MCU sets 
DATA_END at the same time. 
0 
OUT_PKT_RDY  [0]  R  SET  Set by the USB once a valid token is written to the FIFO. 
An interrupt is generated when the USB sets this bit. The 
MCU clears this bit by writing a "1" to the 
SERVICED_OUT_PKT_RDY bit. 
0 