Quick Start Guide

STEP 3. INSTALLING THE POWER CORD
For power cord installations, hook the strain relief over the power cord hole (1
3
/8")
located below the rear of the drawer body. Insert the power cord through the strain
relief and tighten the device.
Strain relief
Power cord
Conduit connection plate
You must install the power cord with a strain relief.
Attach the strain relief to the 1
3
/8" opening in the conduit connection plate.
Installing a 3-wire power cord
WARNING
WARNING
The neutral or ground wire of the power cord must be
connected to the neutral terminal located in the center of the terminal block. The power
leads must be connected to the lower left and the lower right terminals of the terminal block.
1. Remove the 3 lower terminal screws
from the terminal block.
2.
Insert the 3 terminal screws through
each power cord terminal ring and into
the lower terminals of the terminal block.
Be certain that the center wire (white/
neutral) is connected to the center lower
position of the terminal block.
3. Tighten screws securely to the terminal
block. DO NOT remove the ground
strap connection.
4. Go to Step 5 on page 15 to continue
with the installation.
Ground strap
Neutral
terminal
Black
White
Red
Black
White
Red
English - 10