Operation Manual
36_ camera operation
camera operation
COMM ADJ (Communication Adjustment) : This function sets up the camera
communication status when controlling the camera through an external control device.
➊
When the SPECIAL menu screen is
displayed, press the set button so that
the arrow indicates ‘COMM ADJ’.
➋
Set up the mode using the Function
Setup button.
CAM ID : Determines the camera’s identification
number (between 0 and 255).
BAUD RATE : You can select 2400/4800/
9600/19200/38400/57600
bps.
UART MODE : You can select NONE, EVEN or ODD for the parity bits.
RET PKT : Determines whether to send a command back to the controller device
when a communication control command is sent to the camera.
DISP ID : Display camera title on top left corner of the screen.
PROTOCOL : Select the communication PROTOCOL. (SAMSUNG-T, SAMSUNG-E ,
PELCO-D, PELCO-P, BOSCH, HONEYWELL, VICON PANA., GE and AD)
COAX : Specify the use of coaxial communications.
If you encounter an error due to noise from the DVR, you can set the sensitivity
level of the sub menu item to “Low “ in an attempt to prevent the error. Then,
you must press the MENU/ENTER (OSD KEY) button twice in a row to access
the OSD menu.
RETURN : Select this to save the PRIVACY menu settings and return to the
SPECIAL menu.
* Initial value of communication adjustment
Item
Camera ID BAUD RATE UART MODE PET PKT
Initial value
1 9600 8-NONE-1 ENABLE
RETURN : Select this to save the SPECIAL menu settings and return to the MAIN
SETUP menu.
y
-
-
-
-
-
-
-
y
-
y
COMM SETUP
䯝 1. CAM ID
Â
IIIIIIIIIIIIIIIIIIIII
1
2. BAUD RATE 9600
3. UART MODE 8-N-1
4. RET PKT ENABLE
5. DISP ID
OFF
6. PROTOCOL
SAMSUNG-T
7. COAX
ON
8. RETURN