High Resolution Day & Night Dome Camera User Manual SCD-1020P/1020PD SCD-1040P/1040PD Please read the operation manual carefullly before use.. SCD-1020_1040_ENG.
High Resolution Day & Night Dome Camera User Manual Copyright ©2012 Samsung Techwin Co., Ltd. All rights reserved. Trademark is the registered logo of Samsung Techwin Co., Ltd. The name of this product is the registered trademark of Samsung Techwin Co., Ltd. Other trademarks mentioned in this manual are the registered trademark of their respective company. Restriction Samsung Techwin Co., Ltd shall reserve the copyright of this document.
SCD-1020_1040_ENG.indd Before operating the camera, confirm the camera model and correct input power voltage. To help you understand this manual thoroughly, we’ll introduce our model description.
safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
● safety information 3. Do not connect multiple cameras to a single adapter. Exceeding the capacity may cause abnormal heat generation or fire. 4. Securely plug the power cord into the power receptacle. insecure connection may cause fire. 5. When installing the camera, fasten it securely and firmly. The fall of camera may cause personal injury. 6. Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or containers filled with water on top of the camera.
safety information 9. The Mains plug is used as a disconnect device and shall stay readily operable at any time. 10. Do not expose the camera to radioactivity. Radioactivity exposure may damage the CCD. Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.
important safety instructions Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug.
contents introduction 9 10 11 Features What’s included Component names and functions installation 12 12 14 Before Installation Installation Adjust the panning and tilting while watching the monitor connection 15 15 16 Connecting to Monitor Connecting to Power Using Coaxial Communications setup 18 18 Menu Configuration Menu Setup troubleshooting 27 Troubleshooting specifications 28 30 Specifications Dimension 9 12 15 18 27 28 8_ contents SCD-1020_1040_ENG.
introduction Features yy Excellent Sensitivity The built-in high sensitivity COLOR CCD produces a clear image. 0.15Lux(50IRE, @F1.2) ● INTRODUCTION yy High Resolution By adopting a diagonal 6mm(1/3”) 470,000 pixel SONY CCD, the camera produces clear picture quality with a horizontal resolution of 600TV lines in color mode and 650TV lines for BW.
introduction Communication Coaxial communication methods are supported. - Protocol : Pelco Coaxitron Osd The camera control is convenient by using 14 different foreign language O.S.D. English, French, German, Spanish, Italian, Czech, Danish, Polish, Portuguese, Russian, Romanian, Serbian, Swedish, Turkish WhAT’s INClUded Check if the following items are included in the product package. )JHI 3FTPMVUJPO %BZ /JHIU %PNF $BNFSB 6TFS .
COMPONENT NAMES AND FUNCTIONS ● INTRODUCTION SCD-1020_1040_ENG.indd Front 2 3 1 5 8 4 6 7 1 Dome Cover 2 Pan Base : Control panning angle of camera. 3 Lens Module : SCD-1020P - f=3.6mm, F2.0 SCD-1040P - f=8.0mm, F2.0 4 Video Output Terminal to Monitor 5F unction Setup switch : D isplay the menu on the screen and move the cursor to four directions to confirm status or after changing a selected item. 6 Rotate Base : Control rotating angle of camera.
installation Before installation Before installing your camera, you have to read the following cautions: • You have to check whether the location (ceiling or wall) can bear five times the weight of your camera. • Don’t let the cable to be caught in improper place or the electric line cover to be damaged. Otherwise it may cause a breakdown or fire. • When installing your camera, don’t allow any person to approach the installation site. If you have any valuable things under the place, move them away.
● installation SCD-1020_1040_ENG.indd 3) Place the separated ceiling bracket so that the “Front” side faces the area to be monitored and install it with the M4 tapping screws. 4) To combine the main body with the ceiling bracket, make sure that the LOCK at the bottom of the camera matched with the protruding part of the mount bracket and rotate it anti-clockwise. 5) Adjust the camera lens to face the area to be monitored.
installation Adjust the panning and tilting while watching the monitor 90˚ 118˚ 218˚ 231˚ Rotate Base Tilt Base Pan Base 120˚ 1) You can adjust the camera to point in any direction by using the pan, Tilt, Rotate mechanism.
connection Connecting to monitor ● connection Connect the Video Output jack to the VIDEO-IN jack of monitor. Monitor CCTV Camera yy As the connecting method varies with the instruments, refer to the manual supplied with the instrument. yy Only connect the cable when the power is turned off. Connecting to Power Connect the adaptor to the power input connector as shown in the figure below.
connection When the resistance value of copper wire is at [20°C(68°F)] Copper wire size (AWG) #24 (0.22mm2) #22 (0.33mm2) #20 (0.52mm2) #18 (0.83mm2) Resistance (Ω/m) 0.078 0.050 0.030 0.018 Voltage Drop (V/m) 0.028 0.018 0.011 0.006 yy As shown in the table above, voltage decreases as the wire gets longer. Therefore use of an excessively long adaptor output line for connection to the camera may affect the performance of the camera.
ALARM 1 5 DVD RECORDER HDD NETWORK 2 6 BACKUP 3 7 REC REC ● connection SCD-1020_1040_ENG.
setup MENU CONFIGURATION MAIN SETUP EXPOSURE ● BRIGHTNESS ● AGC ● RETURN DEFOG ● AUTO ● OFF ● MANUAL WHITE BAL ● ATW ● MANUAL ● OUTDOOR ● AWC→SET ● INDOOR ● USER BLC BACKLIGHT ● OFF ● HLC SSNR ● ON ● OFF DAY/NIGHT ● AUTO ● COLOR ● B/W SPECIAL ● MONITOR ● SYNC ● COAX ● RETURN ● CAM TITLE ● REVERSE ● SSDR ● PRIVACY ● SHARPNESS ● LANGUAGE EXIT ● SAVE ● NOT SAVE ● RESET MENU SETUP Use the Function Setup switch within the camera. Function Setup switch 18_ setup SCD-1020_1040_ENG.
Select the function using the Function Setup switch up/ down. MAIN SETUP ▶ 1.EXPOSURE 2.DEFOG 3.WHITE BAL 4.BACKLIGHT 5.SSNR 6.DAY/NIGHT 7.SPECIAL 8.EXIT OFF ATW OFF ON AUTO ● setup SCD-1020_1040_ENG.indd 1. Press the Function Setup switch. yy Main setup menu is displayed on the monitor screen. Change the status using the Function Setup switch left/right. SAVE 2. Select a desired function using the Function Setup switch. yy Place the cursor over a desired item. 3.
setup DEFOGGING Through the defogging function, camera can automatically recognize fog concentration of the image, defog, self correct in hazy, rainy, flue gas and other inclement weather to get a clear image. 1. When the SETUP menu screen is displayed, select ‘DEFOG’ by using the Function Setup switch. 2. Select a desired mode. yy AUTO: The camera will automatically correct image according to the defogging level (low, middle, high) set by the user.
yy MANUAL : Select this to fine-tune White Balance manually. Set White Balance first by using the ATW or AWC mode. After that switch to MANUAL mode, fine-tune the White Balance and then press the Function Setup switch. yy AWC→SET : To find the optimal luminance level for the current environment, point the camera towards a sheet of white paper and press the Function Setup switch. If the environment changes, readjust it. ` White Balance may not work properly under the following conditions.
setup HLC (High Light Compensation) : This function masks any areas of peak white light, this HLC SETUP minimizes whiteout due to over exposure and thus preserve MIDDLE ▶ 1. LEVEL much of the on-screen details that are within the camera view. NIGHT ONLY 2. LIMIT - LEVEL : Adjusts the brightness level of a monitoring area. 3. MASK COLOR BLACK 4. RETURN - LIMIT : Enable to change the operating condition. - MASK COLOR :Change the color of the masking area.
You can display pictures in color or black and white. 1. When the SETUP menu screen is displayed, select ‘DAY/NIGHT’ by using the Up and Down buttons so that the arrow indicates ‘DAY/NIGHT’. 2. Select a desired mode using the Left and Right buttons according to the picture display you want. AUTO : The mode is switched to ’Color‘ in a normal AUTO SETUP environment,but switches to ’B/W‘ mode when ambient ▶ DWELL TIME 5 SEC illumination is low.
setup yy CAM TITLE : If you enter a title, the title will appear on the monitor. y 1 If the SPECIAL menu screen is displayed, use the Function Setup switch so that the arrow indicates ‘CAM TITLE’. 2 Set it to ‘ON’ by using the Function Setup CAMERA TITLE SETUP switch. A B C D E F G H I J K L M y 3 Press the Function Setup switch. N O P Q R S T U V W X Y Z y 4 Use the Function Setup switch to move to a desired letter a b c d e f g h i j k l m and select the letter by pressing the switch.
SYNC ▶ PHASE *IIIIIIIIIIIIIIIIIIIII 0 ● setup SCD-1020_1040_ENG.indd yy SYNC : In areas where the supply is at 50Hz(PAL), you can synchronize the output phase of multiple cameras using the power synchronization function (Line-Lock) without using a synchronization signal generator. Press SET to Return -- INT: Internal Synchronization Type -- L/L : Power Synchronization Type, Line-lock nnPress the Function Setup switch. YYYou can select a desired phase from 0 to 359 when select ‘phase’.
setup SSDR ON SSDR OFF y LANGUAGE : You can select the menu language according to your requirements. y RETURN : Select this to save the SPECIAL menu settings and return to the MAIN SETUP menu. eXIt Select a desired EXIT mode using the Function Setup switch depending on the camera purpose. y sAVe : Save the current settings and exit the MAIN SETUP menu. y NOt sAVe : Do not save the current settings and exit the MAIN SETUP menu. y Reset: Resets the camera settings to the factory defaults.
troubleshooting Troubleshooting problem, contact an authorized technician. SCD-1020_1040_ENG.indd PROBLEM SOLUTION Nothing appears on the screen. C heck that the power cord and line connection between the camera and monitor are fixed properly. Check that you have properly connected VIDEO cable to the camera VIDEO output jack. The image on the screen is dim. Is the lens stained with dirt? Clean your lens with a soft, clean cloth. Check the monitor and DVR settings.
specifications Specifications SCD-1020P SCD-1020PD SCD-1040P SCD-1040PD Internal Internal / Line-Lock Internal Video Imaging Device 1/3’’ Super HAD CCD II Total Pixels 795(H) x 596(V) Effective Pixels 752(H) x 582(V) Scanning System 2:1 Interlace Synchronization Internal / Line-Lock Frequency H: 15.625KHz, V: 50Hz Horizontal Resolution COLOR : 600TVL, B/W: 650TVL Min. Illumination 0.15 Lux (50IRE, @F1.2)(AGC: High) S/N (Y Signal) 52dB (Weight On, AGC Off) Video Output CVBS : 1.
SCD-1020P SCD-1020PD SCD-1040P SCD-1040PD Operational English, French, German, Spanish, Italian, Czech, Danish, Polish, Portuguese, Russian, Romanian, Serbian, Swedish, Turkish Camera Title On / Off (Displayed 15 Characters) Day & Night AUTO (Electrical)/COLOR / BW Backlight Compensation OFF/USER BLC / HLC SSDR On / Off Noise Filter(SSNR) On / Off Privacy Masking On / Off (4 Programmable zones) Gain Control Low / High / Middle / Off White Balance ATW / Outdoor / Indoor / Manual / AWC->SE
specifications Dimension Unit: mm(inch) 30_ specifications SCD-1020_1040_ENG.
SCD-1020_1040_ENG.
SALES NETWORK SAMSUNG TECHWIN CO., LTD. Samsungtechwin R&D Center, 701, Sampyeong-dong, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea, 463-400 TEL : +82-70-7147-8740~60, FAX : +82-31-8018-3745 SAMSUNG TECHWIN AMERICA Inc. 100 Challenger Rd. Suite 700 Ridgefield Park, NJ 07660 Toll Free : +1-877-213-1222 Direct : +1-201-325-6920 Fax : +1-201-373-0124 www.samsungcctvusa.com www.samsungtechwin.com www.samsungsecurity.com SCD-1020_1040_ENG.indd 32 SAMSUNG TECHWIN EUROPE LTD.