½
RS-485 Communication establishment initial value.
Item
Camera ID
BAUD RATE UART MODE RET PKT
Initial value
1
9600 8-NONE-1 ENABLE
When making a control system to control the camera, please use to the protocol SAMSUNG-T,
SAMSUNG-E, PELCO-D , PELCO-P, BOSCH, HONEYWELL, VICON, PANASONIC, AD, GE.
When you connecting to RS-485 CONTROL TERMINAL, please peel off the outer skin inside the
RS-485 CONTROL TERMINAL.
USING COAXIAL COMMUNICATIONS
CAMERA
DVR CONTROLLER
SET MENU/ENTER OSD KEY
UP UP KEY JOYSTICK UP
DOWN DOWN KEY JOYSTICK DOWN
LEFT LEFT KEY JOYSTICK LEFT
RIGHT RIGHT KEY JOYSTICK RIGHT
Coaxial Communications System
OSD Control method
If you set the sensitivity level of the sub menu item (of COAX) to “Low”, you have to
press the MENU/ENTER (OSD KEY) button twice in a row to access the OSD menu.
(To prevent an error by noise from the DVR)
(2) Connection to a DVR or System Controller.
Connect the RS-485 cable to the connection ports of the DVR or System Controller.
485 Contr
ol Board Connection Port RS-485 Control Port
(+) CONNECTION
TERMINAL (TRX+)
(-) CONNECTION TERMINAL (TRX-)
y
M
otion detection signals are output through
this terminal.
y
Used for earth-grounding.
(1) Connection to a PC.
Connect the camera to the PC via a RS-485 converter using RS-485 and a serial cable.
EX)
SERIAL PORT OF THE PC(COM1)
SERIAL CABLE
RS-485 CONVERTER
RS-485 CONTROL CABLE
MD
-
OUT:
GND: