User guide

SPEED DOME CAMERA User Guide
18
SPEED DOME CAMERA User Guide
19
ON
ON
OFF
SW1
Function ON OFF
SW2- #7 Response Mode Switch Response No Response
Select a communication response method for the camera and controller: Response or No
Response.
•
Communication Response Settings
Camera Input Position SW2- #8
Termination of Longest Path ON
On the Path OFF
To prevent the attenuation of communication signals between the camera and controller,
the items at the end of line must be set up with the termination settings.
•
Termination Settings
•Touseathirdpartycontrollerwiththisproduct,pleasecontactourAfter-SalesServiceor
Technology Department.
•ControlsUsingDifferentProtocols
•Formoreinformationabouttheprotocols,refertoourofficialwebsite.
Notes
To set up camera IDs, refer to the “Camera ID Chart” next.
Camera ID DIP Switch Settings (SW1)
Installing Your Camera
* This model is provided with factory defaults of all DIP switches set to OFF. The default
settings are shaded in the table.
•
Camera ID Chart
ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8
1 ON/OFF OFF OFF OFF OFF OFF OFF OFF
2 OFF ON OFF OFF OFF OFF OFF OFF
3 ON ON OFF OFF OFF OFF OFF OFF
4 OFF OFF ON OFF OFF OFF OFF OFF
5 ON OFF ON OFF OFF OFF OFF OFF
6 OFF ON ON OFF OFF OFF OFF OFF
7 ON ON ON OFF OFF OFF OFF OFF
8 OFF OFF OFF ON OFF OFF OFF OFF
9 ON OFF OFF ON OFF OFF OFF OFF
10 OFF ON OFF ON OFF OFF OFF OFF
11 ON ON OFF ON OFF OFF OFF OFF
12 OFF OFF ON ON OFF OFF OFF OFF
13 ON OFF ON ON OFF OFF OFF OFF
14 OFF ON ON ON OFF OFF OFF OFF
15 ON ON ON ON OFF OFF OFF OFF
16 OFF OFF OFF OFF ON OFF OFF OFF
17 ON OFF OFF OFF ON OFF OFF OFF
18 OFF ON OFF OFF ON OFF OFF OFF
19 ON ON OFF OFF ON OFF OFF OFF
20 OFF OFF ON OFF ON OFF OFF OFF
21 ON OFF ON OFF ON OFF OFF OFF
22 OFF ON ON OFF ON OFF OFF OFF
23 ON ON ON OFF ON OFF OFF OFF
24 OFF OFF OFF ON ON OFF OFF OFF
25 ON OFF OFF ON ON OFF OFF OFF
26 OFF ON OFF ON ON OFF OFF OFF
27 ON ON OFF ON ON OFF OFF OFF
28 OFF OFF ON ON ON OFF OFF OFF
29 ON OFF ON ON ON OFF OFF OFF
30 OFF ON ON ON ON OFF OFF OFF
31 ON ON ON ON ON OFF OFF OFF
32 OFF OFF OFF OFF OFF ON OFF OFF
33 ON OFF OFF OFF OFF ON OFF OFF
34 OFF ON OFF OFF OFF ON OFF OFF
35 ON ON OFF OFF OFF ON OFF OFF
36 OFF OFF ON OFF OFF ON OFF OFF
37 ON OFF ON OFF OFF ON OFF OFF
38 OFF ON ON OFF OFF ON OFF OFF
39 ON ON ON OFF OFF ON OFF OFF
40 OFF OFF OFF ON OFF ON OFF OFF
41 ON OFF OFF ON OFF ON OFF OFF
AD Protocol VICON Protocol GE Protocol
Entering Camera OSD 3+Auxilary ON IRIS OPEN IRIS OPEN
Exiting Camera OSD 3+Auxilary OFF IRIS CLOSE IRIS CLOSE
ENTER IRIS OPEN IRIS OPEN IRIS OPEN