User guide

SPEED DOME CAMERA User Guide
74
SPEED DOME CAMERA User Guide
75
P (Priority)
:
Set the priority of Alarm Inputs. If more than one alarm is simultaneously activated,
the alarm with the highest priority activates before the others. Once the alarm is canceled, the
next highest priority alarm activates.
SEQ
:
Enables setting up a sequence action for the camera in response to an alarm. Available
sequence actions are Home, Preset, Swing, Group, Tour, Trace and A.Pan.

For the Auto Pan settings, the first number under the Number menu indicates the speed
while the second is the Tilt angle. (Refer below.)
MD Dwell Time
:
When Motion Detection under the Preset Edit menu is selected, MD Dwell Time performs the
Tour or Group function.
While the camera is performing a sequence action, if motion is detected from a selected preset
location, the camera pauses the sequence action operation and starts monitoring the location
instead for a duration that is set under the MD Dwell Time menu.
If the motion is no longer detectable or the duration expires, the camera aborts the monitoring
operation and then resumes the sequence action.
•Asshowninthepictureabove,theAlarmInputmustbeenteredwiththeOpenorClosed
switch signals. Supplying power without entering the signals may damage the product.
Notes
Functional Description
ALM MOD P SEQ NO
Input 1 NO 1 Auto Pan 20/20
Input 2 NC 2 Auto Pan 20/20
Tilt Angle
Speed
Alarm Output
Setting1
1 2
MD
AUX
Setting2
1 2
MD
AUX
Timer OFF
Timer OFF
OUT Off1
OUT Off2
29.2. Alarm Output
Main Menu/Alarm Setting/Alarm Output
Timer
1,2 :
Enables selecting an Alarm Output method.
- On : Retains an alarm output for a set duration from a
minimum of 1 second to a maximum of 60 minutes
upon the alarm occurrence.
- Momentary : Retains an alarm output only until the alarm
is canceled.
Setting 1,2 :
Enables selecting an Alarm Output method.
- 1, 2, Motion, and Support Device indicate alarm input
ports, Motion Detection, and support device input. A total
of 4 alarms, Motion Detection, and support devices can be
set up to output alarms. 1 alarm output port can be used
for more than 2 alarm inputs and Motion Detection.
The Alarm Output is equipped with a relay circuit. The
operation of the alarm output port is as shown in the
diagram below.
•ConnectingthepowerconnectorandGNDincorrectlytotheNC/NOandCOMportsmay
cause a short circuit and fire, damaging the camera.
•Themaximumpowercapacityofthebuilt-inrelayis30VDC/2A,125VAC/0.5A,and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera’s
lifespan and damage it.
Notes
NO NO
NC NC
COM COM
Alarm Out OFF Alarm Out ON
Alarm Setting
Alarm Enable OFF
Alarm Input
Alarm Output
MD Dwell Time OFF
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status