User guide

SPEED DOME CAMERA User Guide
16
SPEED DOME CAMERA User Guide
17
ON
ON
OFF
SW2
*
Coaxial communication automatically detects signals, and so does not require a
separate communication setup process.
Communication Protocol DIP Switch Settings (SW2)
•
Protocol Settings
No Protocol SW2-#1 SW2-#2 SW2-#3 SW2-#4
1 AUTO DETECT OFF OFF OFF OFF
2 Samsung OFF OFF OFF ON
3 Pelco-D OFF OFF ON OFF
4 Pelco-P OFF OFF ON ON
5 Samsung Elec OFF ON OFF OFF
6 Panasonic OFF ON OFF ON
7 Vicon OFF ON ON OFF
8 Honeywell OFF ON ON ON
9 AD ON OFF OFF OFF
10 GE ON OFF OFF ON
11 BOSCH ON OFF ON OFF
12 Resetved ON OFF ON ON
13 Resetved ON ON OFF OFF
14 Resetved ON ON OFF ON
15 Resetved ON ON ON OFF
16 Resetved ON ON ON ON
Select a communication protocol for the camera
SW2 Pin No. Purpose
1~4 Protocol Settings
5~6 Baud Rate Settings
7 Response Mode Settings
8 Termination Settings
Installing Your Camera
How to Set Up Protocols and ID DIP Switches
You can control various settings of the camera system using the Communication and ID
DIP switches. Before installing the product, please set up the DIP switches according to
the installation environment.
1. Detach the camera frame from the install base, and place the bottom of the frame
toward you as shown in the picture below.
2. Set the switches according to your installation environment. For more detailed setup
information, please refer to the chart on the next page.
3. The camera may malfunction if the switches are not fully turned On/Off; please double
check the switches before finishing setup.
Communication Protocol DIP Switch(SW2)
Camera ID DIP Switch(SW1)
No. Baud Rate(BPS) SW2-#5 SW2-#6
1 2,400 ON ON
2 4,800 ON OFF
3 9,600 OFF OFF
4 19,200 OFF ON
Select the transfer speed of a selected communication protocol.
•
Baud Rate Settings