* This diagram is based on SDC-313(243)NA/PA
Video Out Jack
Connect to the video input connector of monitor. This jack outputs a composite
video signal. Use a coaxial cable for connection.
Auto lris Lens Connector
Used to connect auto iris lens plug.
Auto IRIS Lens Selection Switch
Used to choose DC or VIDEO mode according to the type of your lens.
Using Auto Iris Lens
You can choose DC or VIDEO mode according to the type of the lens. ln this
case, electronic shutter is fixed in ‘1/60’sec (NTSC models), ‘1/50’sec (PAL models).
Using Manual Lens
Using manual lens, you can choose any switch selection. When the switch is
set to ‘OFF’ in ESC mode, the electronic shutter is fixed in ‘1/60’sec (NTSC
models), ‘1/50’sec(PAL models). When the switch is set to ‘ON’ in ESC mode,
the electronic shutter automatically controls the shutter speed from ‘1/60’ to
‘1/120,000’sec (NTSC models), ‘1/50’ to ‘1/120,000’sec (PAL models).
DC Level Adjustment V.R
Used to adjust video output level of DC driven auto iris lens. When the
brightness control of the monitor does not operate correctly, you can get the
optimum picture by controlling the DC level of camera.
V. PHASE Adjustment V.R: AC type
If the camera is to be used in the LL mode, the vertical phase may require
adjustment to synchronize the vertical phase of the camera with other camera
in the system. Make this adjustment when the vertical phase of the camera
does not match with other cameras or systems. For correct adjustment, use a
multi - channel oscilloscope. The V. PHASE adjustment can be readjusted in the
range of 0 to 270 degrees.
• Using auto iris lens, you must select ‘OFF’ of the ESC selection switch.
Notes
Monitor Picture Adjustment direction
To make it brighter Turn clockwise
Monitor Picture Adjustment direction
To make it darker
Turn counterclockwise
You must select ‘OFF’ of the ESC selection switch if you want to adjust DC level adjustment V. R.
Notes
• This adjustment is necessary only when linelock is performed.
• There is no V. PHASE adjustment VR on the rear of DC power type.
Notes
Name and Function of Each Part
SDC-313,243() 2003.6.26 5:1 PM 페이지10