Split-type Room Air Conditioner (Cool and Heat) Aire acondicionado doméstico sistema Split (Refrigeración y Calefacción) Climatiseur de type Séparé (Refroidissement et Chauffage) Condizionatore d’aria per ambienti ad unità Separate (Raffreddamento e Riscaldamento) Aparelho de ar condicionado tipo Split (Refrigeração e Aquecimento) Geteilte raumklimaanlage (Kühlen und Wärmen) ENGLISH ESPAÑOL UQ07P8GE UQ07PBGE SH07ZPGX SH07ZPGAX UQ09P8GE UQ09PBGE SH09ZPGX SH09ZPGAX UQ12PBGE UQ12PGGB UQ12PGGE SH12ZPGX SH12ZP
Safety Precautions WARNING DANGER ◆ If the power supply cord of this air conditioner is damaged, it must be replaced by the manufacturer or its authorized service personnel only in order to avoid a safety hazard. ◆ Do not attempt to install the air conditioner by yourself. ◆ This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs. ◆ When moving, consult authorized service personnel for disconnection and installation of the unit.
ENGLISH Contents ◆ PREPARING YOUR AIR CONDITIONER ■ Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . . . ■ Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . . . .
View of the Unit The design and shape are subject to change according to the model. Indoor Unit Air Inlet Auto grille Room temperature sensor On/Off switch Air filter (under the grille) Remote Control Sensor Air flow blades (outlet) Operation indicator Timer indicator Set temperature & room temperature Sleep Timer indicator Anion indicator Fan speed setting Note E-4 ◆ If you want to turn on/off the Display during operation, press the button on the remote control.
ENGLISH Outdoor Unit UQ07P8GE UQ09P8GE Air Inlet(Rear) SH30ZC1(C2)X Air Outlet Connection Valve (inside) Outdoor Unit UQ07PBGE UQ09PBGE UQ12PBGE Air Inlet(Rear) Air Outlet Connection Valve Outdoor Unit SH07ZPGX UQ12PGGB SH07ZPGAX SH09ZPGX UQ12PGGE SH12ZPGX SH09ZPGAX SH12ZPGAX Air Inlet(Rear) Air Outlet Connection Valve (inside) Outdoor Unit UQ18P0GB UQ24P6GB UQ18P0GE SH18ZP0X UQT24P6GE SH24TP6X SH18ZP0AX SH24TP6AX Air Inlet(Rear) Air Outlet Connection Valve E-5
Remote Control - Buttons and Display Remote control transmission indicator Battery discharge indicator Fan speed Anion indicator Sleep mode Operating mode ( AUTO, FAN, COOL, HEAT) DRY, Turbo mode Temperature setting Air flow direction Off Timer setting On Timer setting Energy saving On/Off button Temperature adjustment buttons Digital i On/Off button Mode selection button (AUTO, COOL, DRY, FAN, HEAT) Swing button Fan speed adjustment button Sleep button On Timer button Off Timer button E-6 Energy
ENGLISH Getting Started You have just purchased a split type air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features. The booklet is organized as follows.
Inserting the Remote Control Batteries You must insert or replace the remote control batteries when : ◆ You purchase the air conditioner ◆ The remote control does not work correctly Note E-8 ◆ ◆ ◆ ◆ Use two AAA, LR03 1.5V batteries. Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used.
ENGLISH Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the optimum temperature and the fan speed is selected automatically. 1 If necessary, press the Result: IMPORTANT (On/Off) button. ◆ The operation indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps.
Cooling Your Room You must select the Cool mode if you wish to adjust the: ◆ Cooling temperature ◆ Fan speed when cooling 1 If necessary, press the Result: IMPORTANT (On/Off) button. ◆ The operation indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps.
ENGLISH Heating Your Room You must select the Heat mode if you wish to adjust the: ◆ Heating temperature ◆ Fan speed when heating 1 If necessary, press the Result: IMPORTANT 2 Note ◆ The indoor unit beeps each time you press the ◆ The air conditioner runs in HEAT mode. You can change modes at any time. button. To adjust the temperature, press the button one or more times until the required temperature is displayed. Possible temperatures are between 16°C and 30°C inclusive.
Changing the Room Temperature Quickly The Turbo cooling/heating function is used to cool or heat your room as quickly as possible. Example : You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected. 1 If necessary, press the Result: 2 Press the Result: (On/Off) button.
ENGLISH Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. 1 If necessary, press the Result: ◆ The operation indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps. IMPORTANT 2 Note ◆ The indoor unit beeps each time you press the ◆ The air conditioner runs in DRY mode. You can change modes at any time.
Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. 1 If necessary, press the Result: 2 If the is not displayed at the top of the remote control, press the button on the remote control one or more times until it appears. Result: Note 3 (On/Off) button. ◆ The operation indicator on the indoor unit lights up. ◆ The air conditioner starts up in the mode selected when the unit was last used. ◆ The indoor unit beeps.
ENGLISH Selecting Energy Saving Mode If you wish to save energy when using your air conditioner, select the Energy saving mode with the Energy saving button. 1 If necessary, press the Result: IMPORTANT 2 button. You can select the Energy saving mode only in COOL mode. Press the Result: 4 The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being: ◆ Plugged in ◆ Stopped lt will start up normally after three minutes.
Generating anion The air conditioner can generate anion with an ionizer in the indoor unit. Since it is an additional function, you can select it any mode, even when the air conditioner is turned off. 1 Press the Result: button. ◆ The air conditioner generates anion. ◆ The indoor unit beeps. Note E-16 If you press the button during off, the air conditioner will turn on automatically and generate anion in the Fan mode with Low fan speed.
ENGLISH Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. 1 Press the Result: button one or more times as required. The outer blade is adjusted vertically. RECOMMENDATION 2 When... Adjust the blade to face... Cooling Heating Upwards. Downwards.
Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusive. 2 Press the Result: 3 (Set/Cancel) button to complete the setting. ◆ The remaining time is displayed. ◆ Blinking of the timer indicator stops.
ENGLISH Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 1 To set the operating time, press the button one or more times until the required time is displayed. Possible time is between 0.5 hour and 24 hour inclusive. 2 Press the Result: (Set/Cancel) button to complete the setting. ◆ The remaining time is displayed. ◆ Blinking of the timer indicator stops.
Setting the Sleep Timer The Sleep Timer can be used when you are cooling or heating your room to switch the air conditioner off automatically after a period of six hours. Note If you wish to switch the unit off at a specific time, refer to page 19. 1 Make sure that you have selected either COOL or HEAT mode. 2 Press the button. ◆ The indoor unit beeps. ◆ The air conditioner will be controlled as indicated in the illustrations below.
ENGLISH Operating Recommendations Here are a few recommendations that you should follow when using your air conditioner. Topic Recommendation Heating performances The heat pump inside the air conditioner absorbs heat from outside air and brings it indoors. If the temperature of the outside air drops, the air conditioner will heat less. If you find that the room is not warm enough, use an additional heating appliance.
Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... Then... High temperatures The automatic protection feature may be triggered and the air conditioner stopped. Low temperatures A water leak or some other malfunction may occur if the heat exchanger freezes.
ENGLISH Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Explanation/Solution Problem The air conditioner does not operate at all ◆ Check that the breaker used for the air conditioner is switched on. ◆ Check that the operation indicator on the indoor unit is on; if necessary press the (On/Off) button on the remote control.
Cleaning Your Air Conditioner To get the best possible use out of your air conditioner, you must clean it regularly to remove the dust that accumulates on the air filter. IMPORTANT Grille support Lower front grille Body groove 1 Slide the lower front grille down. 2 Slide the upper front grille up slightly, then open the grille by pulling right and left sides of the grille. 3 Disassemble the upper front grille by opening the grille completely.
ENGLISH Technical Specifications Model Indoor unit Power Supply AQ07P8GE AQ07PBGE SH07ZPG SH07ZPGA AQ09P8GE AQ09PBGE SH09ZPG SH09ZPGA AQ12PBGE AQ12PGGE 220-240V~, 50Hz SH12ZPG SH12ZPGA AQ18P0GE SH18ZP0 SH18ZP0A AQT24P6GE SH24TP6 SH24TP6A AQ12PGGB AQ18P0GB 220V~, 60Hz AQ24P6GB E-25
THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: DIESE KLIMAANLAGE IST FABRIZIERT VON: AYTH H ™Y™KEYH KATA™KEYA™THKE A¶O: ELECTRONICS