Quick Guide (Dimmer / Transformer compatibility list) (ver.1.0)

SAMSUNG ELECTRONICS LED Lamp
PAR30_LN (75W Equivalent)
Dimmable PAR30_LN _15.0W
Product Code Bar Code Specification
SI-P9W163CB1US 887276988078 760lm / 15.0W / 25D / 2700K / E26
SI-P9W163CD1US 887276988085 760lm / 15.0W / 40D / 2700K / E26
Dimmer Compatibility
Dimmer Compatibility
[US] _09 Mar 2013
Samsung LED Lamps are compatible with most forward phase dimmers and dimming systems. They are not compatible with reverse phase or ELV dimmers.
Dimmer
Dimming Level
@ 1 lamp (flux%)
Dimming Performance
@ Multi-Lamps
Manufacturer
Model
Power
Input
Frequency
Country/
Region
Max
2 Lamp
3 Lamp
4 Lamp
5 Lamp
LUTRON
TG-600P
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LUTRON
MIR-600M-WH
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LUTRON
S-600PH-WH
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LEVITON
IP106
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
GE
6633-P
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LEVITON
6683
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LEVITON
700I
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LEVITON
OG38L1
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
GE
18020
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LUTRON
DV-600P-WH
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LEVITON
6641
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LEVITON
IPI10-1LZ
1000W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LEVITON
6602
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
COOPER
9530W
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
COOPER
9532W
1000W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
GE
52129
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
GE
18025
1000W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LUTRON
GL-600P-WH
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LUTRON
NT-603P
1500W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LUTRON
DVCL-153P-WH
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
COOPER
RI061
600W
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LUTRON
GRAFIK Eye
-
120V
60Hz
USA
GOOD
GOOD
GOOD
GOOD
LEVITON
81500-W
1500W
120V
60Hz
USA
not compatible
not compatible
LEVITON
82000-W
2000W
120V
60Hz
USA
not compatible
not compatible
Note 1. Dimming Performance : Good(Dimming Coverage without flicker : 75% ↑), Working(41~74% ), Poor(40% ↓)
2. This result can only be used as reference. The result may vary according to actual field conditions.
Optimum Range Optimum Range