Operation Manual

External PTZ setup (SNB-5003/SNB-5004)
Configure the connection settings to the external pan/tilt receiver so that you can control
the PTZ operations via the receiver connected to the RS-485 port of the camera.
1. Select the <Video & Audio (
)> tab
from Setup menu.
2. Click <External PTZ setup>.
3. Specify the serial port.
You can set the RS-485 communication
mode for pan/tilt-compliant receiver that
is connected to the network camera.
Protocol : From SAMSUNG-T/
SAMSUNG-E / PELCO-D/PELCO-P
/ SUNGJIN, select the same protocol
as that of the receiver.
Camera ID : Displays the fixed
camera ID.
Baudrate : Transfer rate for RS-485
communications.
Data bit : Specify the data bit.
Parity bit : Specify the parity bit.
Stop bit : Specify the stop bit.
4. When done, click [Apply (
)].
M
`
All these operations above mentioned will be enabled only if the network camera is properly
connected to the pan/tilt-compliant receiver. And the serial port for the pan/tilt operations should
be properly specified.
J
`
Check the functions supported by the receiver when it is connected.
Some functions may be disabled depending on the receiver or protocol specification.
Refer to the following table for more details.
Functions Supported for Each Protocol
PT Control
PT
Movement
Speed
Zoom
Control
Zoom
Movement
Speed
Focus
Control
Focus
Control
Speed
Preset
SAMSUNG-T O O O O O O O
SAMSUNG-E O O O O O X O
PELCO-D O O O X O X O
PELCO-P O O O X O X O
SUNGJIN O X X X X X O
English _89
SETUP SCREEN