User manual

English _17
INSTALLATION & CONNECTION
Communication Protocol DIP Switch Settings (SW1)
SW1 Pin No. Purpose
1~4 Protocol Settings
5~7 Baud Rate Settings
8 Termination Settings
Protocol Settings
Select a communication protocol for the camera.
No. Protocol SW1-#1 SW1-#2 SW1-#3 SW1-#4
1 AUTO DETECT OFF OFF OFF OFF
2 SAMSUNG-T ON ON ON OFF
3 PELCO-D ON OFF OFF OFF
4 PELCO-P OFF ON OFF OFF
5 SAMSUNG-E ON ON OFF OFF
6 Panasonic OFF OFF ON OFF
7 GE ON OFF ON OFF
8 AD OFF ON ON OFF
9 VICON OFF OFF OFF ON
10
Honeywell
(KD6)
ON OFF OFF ON
11 BOSCH OFF ON OFF ON
12
Honeywell
(VCLTP)
ON ON OFF ON
y
ON
ON
OFF
SW1