Baud Rate Settings
Select the transfer speed of a selected communication protocol.
No. Baud Rate (BPS) SW1-#5 SW1-#6 SW1-#7
1 2400 OFF OFF OFF
2 4800 ON OFF OFF
3 9600 OFF ON OFF
4 19200 ON ON OFF
5 38400 OFF OFF ON
Termination Settings
To prevent the attenuation of communication signals between the camera and controller,
the items at the end of line must be set up with the termination settings.
Camera Input Position SW1- #8
Termination of Longest Path ON
On the Path OFF
The default value is shaded in each setting table.
To use a third party controller with this product, please contact our After-Sales Service or
Technology Department.
Camera ID DIP Switch Settings (SW2)
To set up camera IDs, refer to the “Camera ID Chart” next.
y
y
M
ON
ON
OFF