SSA-P102 SSA-P102T Access Control Panel user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please visit our website. www.samsungsecurity.
safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
5. Keep out of direct sunlight and heat radiation sources. It may cause fire. 6. Install it in a place with good ventilation. 7. Avoid aiming the controller directly towards extremely bright objects such as sun. 8. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. 9. The Mains plug is used as a disconnect device and shall stay readily operable at any time.
contents 5 6 9 FeatureS What’s included Cable Selection 10 10 11 12 15 Connecting the termination resistor and diode Earth-grounding the communication cables Power, Reader, and I/O Connection Communication Line Connection INITIALIZATION 19 19 20 20 System Initialization Reader Input Bit Setup Board ID Setting Communication Speed Setup 21 Troubleshooting 23 Product Specifications PRODUCT INTRODUCTION 5 INSTALLATION AND EXTERNAL CONNECTION 19 TROUBLESHOOTING 21 PRODUCT SPECIFICATIONS 23 4_ co
product introduction FEATURES Standalone Operation As it is equipped with two card readers, you can use this product to control the access on a single door. This controller determines to allow access by reading data from the card reader, and controls the open/close of the door relay and enables you to change other output settings. Upon receipt of an incoming external input signal (sensor or Exit button), it launches an output device such as the relay.
product introduction Time Scheduling You can specify a time range during which a specific operation is performed. You can specify a specific time range for a schedule code, which will be transferred to the applicable device. You can specify up to 5 different time ranges for a day, ranging from Monday to Sunday including holidays. Each time schedule code can be applied with a single different (or same) holiday code.
Main Board 2 3 4 5 6 1 14 30 7 20 8 21 9 22 10 23 11 12 24 17 15 25 18 26 16 19 27 28 29 1 Fixing Hole Used to attach SSA-P102 to the closure using a metal supporter. (Ensure that you use the metal supporter to prevent the EMI.) 2 2Pin DIP Switch Used to set the type of a connected reader to either 26bit Wiegand or 34bit Wiegand.
product introduction 10 Input #3 Input Port: The flashing LED indicator denotes that a signal is sensed by the port. 11 Input #2 Input Port: The flashing LED indicator denotes that a signal is sensed by the port. (connected to the Door Contact Sensor.) All other sensors are not allowed. 12 Input #1 Input Port: The flashing LED indicator denotes that a signal is sensed by the port. (connected to the Exit button.) All other input sources are not allowed.
CABLE SELECTION RS-232 RS-422/RS-232 Converter PRODUCT INTRODUCTION HOST PC RS-422 RS-422 RS-422 DC12V Power Supply RF Reader Lock/Alarm Exit Button/Sensor Input Item DC12V Power Supply RF Reader Lock/Alarm Exit Button/Sensor Input Cable Type 1 DC 12V Product Power This product 2 Reader (Power and Data) External Reader This product Belden #9512, 22 AWG 4 Conductor, Shielded Belden #9512, 22 AWG 4 Conductor, Shielded 3 Door Contact Sensor
installation and external connection CONNECTING THE TERMINATION RESISTOR AND DIODE Termination Resistor A resistor is inserted for matching the line’s impedance to prevent distortion and reduction in RS-422 or RS-485 long distance data communications, which is referred to as termination resistor. Note that termination resistors of lower than 90 are not allowed, neither more than one termination resistor is accepted for the communications system.
EARTH-GROUNDING THE COMMUNICATION CABLES We recommend you to use a proper grounding system for the communication cables. 1. Earth Ground 2. Chassis Ground 3. Power Ground The most important thing about the earth-grounding lies in connecting neither end of the shield wire to the grounding system simultaneously.
installation and external connection POWER, READER, AND I/O CONNECTION Power Connection Check the location of the power port. DC +12V GND - Connect the plus (+) line of DC 12V to the corresponding port (+12V). - Connect the plus (-) line of DC 12V to the GND (-) port.
Input Connection Door Contact Exit Button PUSH GND INPUT #2 GND INPUT #1 - The Input #1 and Input #2 ports have the Exit button and the Door Contact Sensor installed, while Input #3 to Input #5 can be configured to your preference. - Exit Button Connection Connect one line of the Exit button to IN 1. Connect the other line of the Exit button to GND. - Door Contact Sensor Connection Connect one line of the Door Contact Sensor to IN 2. Connect the other line of the Door Contact Sensor to GND.
installation and external connection Output Connection + COM Normal Open NO - +12V GND NC + COM Normal Close - Cathode Anode 1N4004 ~ 1N4007 or equiv. +12V GND - According to the operation mode, the Door Lock type is classified in two: NC (Normal close) and NO (Normal Open). Make the connection as appropriate. - To prevent a risk of voltage surge during the lock operation, it is recommended to use the bypass diode. - If the Door Lock type is POWER FAIL SAFE 1.
COMMUNICATION LINE CONNECTION RS-232 Communication Port Connection A 9-pin connector for serial communication is required to make connection to the PC. Connect the 9 pin connector for RS-232 communications as follows: INSTALLATION AND EXTERNAL CONNECTION HOST PC RS-232 2 3 5 9-Pin Female Connector 1. Connect RS-232-TX to pin #2 of the 9-pin connector. 2. Connect RS-232-TX to pin #3 of the 9-pin connector. 3. Connect RS-232-GND to pin #5 of the 9-pin connector. 4.
installation and external connection RS-422 Communication Port Connection (Standalone) The RS-422/RS-232 converter is required to establish RS-422 communications. Connect the 9-pin connector of the RS-422/RS-232 converter as follows: RS-422/RS-232 Converter RxD TxD Power RS-232C HOST T+ T- R+ R- MAX. 1200m TXTX+ RXRX+ 1. Connect RS-422-TX(-) to the RX(-) port of the converter. 2. Connect RS-422-TX(+) to the RX(+) port of the converter. 3. Connect RS-422-RX(-) to the TX(-) port of the converter. 4.
RS-422 Communication Port Connection (Multiple Units) The RS-422/RS-232 converter is required to establish RS-422 communications with SSA-P102. RS-422/232 Converter RxD TxD Power T+ T- R+ R- INSTALLATION AND EXTERNAL CONNECTION RS-232C HOST MAX. 1200m TXTX+ RXRX+ SSA-P102 - Follow the guidelines below to make connection between devices. 1. Connect TX(-) of one device to TX(-) of other one. 2. Connect TX(+) of one device to TX(+) of other one. 3. Connect RX(-) of one device to RX(-) of other one. 4.
installation and external connection TCP/IP Communication Port Connection 1) TCP/IP Communication Connection HUB TCP / IP PC J TCP / IP SSA-P102T is required to establish TCP/IP communications. 2) Cabling Connect the LAN cable to the TCP/IP RJ-45 jack as shown. 1. Connect the RJ45 jack of the unit to the RJ45 plug, the LAN cable of the network system. 2. Set a unique communication address (COMM ADDR) for each unit 3. Install and launch the application (SAMS).
Initialization SYSTEM INITIALIZATION Initializing the system using the Initialize switch INITIALIZATION Apply the power and initialize the system by using the initialization switch. Initialize Switch 1. Locate the Initialize switch ( ) on the upper right corner and press both switches simultaneously. • Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep. Releasing both switches will stop the beep, and restarts the system after the initialization.
initialization BOARD ID SETTING Device Address and Communication Speed Each device in the multi-serial communication connection is assigned with a unique number to identify each other. 1. The initial value of the switch is “0”, and all of the 8 switches are defaulted to OFF. 2. Each switch has a unique value, and the board ID is the sum of the values of the switches. KS022H ON 1 • You can specify a value between 0 and 31 for the board ID.
troubleshooting TROUBLESHOOTING If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact the SAMSUNG Customer Service near you. Problem Action 1) 2) It is not available. The mode is defined for each reader device, not the card. Thus, you can not specify the mode for each card differently. Ever since I mass-transferred data using the PC application, some cards are not allowed for access.
troubleshooting The reader reads a card normally but no reaction is made to SSA-P102 or an irrelevant card number is displayed. 1) 2) 3) 4) 5) No communication is available when the system is in sync with the PC. Check the power source of the reader. (Check if the LED indicator of the reader is blinking when it has read a card.) Check if the reader works properly. (Disconnect the reader from the system and use a measuring device such as an oscilloscope to measure the output port of the reader.
product specifications PRODUCT SPECIFICATIONS SSA-P102 Item SSA-P102T Users 10,000 ~ 50,000 Users (Default: 10,000) Event Buffer 50,000 ~ 100,000(Default: 50,000) Power / Current DC 12V / Max.120mA Reader Port 2ea : 26bit/ 34bit Wiegand(Selectable), 4 / 8bit Burst for PIN Door Open Time 00~99 Sec. (Default 3Sec.
Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life.