SSA-S2000 Standalone RFID Access Controller user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please visit our website. www.samsungsecurity.
safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
5. Keep out of direct sunlight and heat radiation sources. It may cause fire. 6. Install it in a place with good ventilation. 7. Avoid aiming the controller directly towards extremely bright objects such as sun. 8. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. 9. The Mains plug is used as a disconnect device and shall stay readily operable at any time.
contents 6 7 8 9 Features What’s included At a Glance Cable Color Scheme 10 11 12 12 14 Installing the rear template Cable Selection Bypass Diode Connection I/O Connection External Reader Connection INITIALIZATION 15 16 16 17 17 Basic Operations Wiegand Output Setup Initialization Forced Initialization with External Line Hardware Forcible Initialization READER MODE SETUP 18 19 19 20 Reader Mode Setup (RF ONLY) Reader Mode Setup (RF + P/W) Reader Mode Setup (PIN ONLY) Reader Mode Setup (RF/PIN Combi
I/O TIME SETUP 30 29 30 31 ADVANCED SETTING 34 34 34 35 35 36 36 37 37 38 38 ADDITIONAL FEATURES 39 38 39 OTHER INFORMATION 42 TROUBLESHOOTING To specify the TTL output operation mode To set the chime bell function To specify the chime bell operation time To specify the input mode for AUX 1 To specify the input mode for AUX 2 To specify the input mode for AUX 3 To specify the input mode for the Exit Button To specify the input mode for the Door Contact Sensor Mute To specify the use of the tamp
product introduction FEATURES This controller is best designed for a single entry door control (single door access control). It can store up to 512 cards including the Master Card that enables you to register, delete or set various user cards to your preference. This product features 5 external ports that can be connected to the Exit button, Door Contact Sensor, Motion Sensor, and Fire Sensor. It also has 2 relay outputs that can control the door lock and alarm relay.
WHAT’S INCLUDED Check if the following items are included in the product package. Y [ \ Z ^ _ ` lzj W lu{ ] i zzhTzYWWW Main Unit Template O-rings (x5) xGn 3.5 x 40mm Screws (x4) 3.
product introduction AT A GLANCE Front View X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW System Status LED Indicates the operation status of the system. Keypad Use this to configure or release settings as appropriate, or enter a card number.
CABLE COLOR SCHEME ❖ 2-PIN Connector I/O Pins Signal Cable Color DC +12V Red Earth-grounding GND(-) Black PRODUCT INTRODUCTION Power (+12V) ❖ 10-PIN Connector I/O Pins Door Control Relay (NC) Signal NC(RL1) Cable Color Blue with White stripes Door Control Relay (COM) COM(RL1) Gray with Red stripes Door Control Relay (NO) NO(RL1) White with Red stripes Alarm Relay (NC) NC(RL2) Purple with White stripes Alarm Relay (COM) COM(RL2) White Alarm Relay (NO) NO(RL2) Purple Exit Button E
installation and external connection INSTALLING THE REAR TEMPLATE O-ring O-ring 6-32 hole 1.85"(47mm) 1/2” hole 2.05"(52mm) O-ring 1.55"(39.5mm) O-ring 1.79"(45.5mm) 6-32 hole O-ring 1.52"(38.5mm) 1.52"(38.5mm) 3.03"(77mm) J Once the main unit is fixed with the rear panel, it will not be loosened. Please check if the device is operating before fixing it.
CABLE SELECTION Y Z [ \ ] ^ _ ` lzj W lu{ INSTALLATION AND EXTERNAL CONNECTION X DC12V Power Supply i zzhTzYWWW RF Reader Item 1 Power (DC12V) DC Power This Product 2 Reader (power and data) External Reader This Product 3 Door Contact Sensor Exit Button Sensor Input Input This Product 4 Door Lock, Alarm Device Lock (Alarm) This Product J Sensor Input Lock/Alarm Cable Type Belden #9409, 18 AWG 2 Conductor, Unshielded Belden #9512, 22 AWG 4 Conductor, Shield
installation and external connection BYPASS DIODE CONNECTION If you connected an inductor (door locks or alarm device) to the output relay, there should occur a voltage surge while the inductor is turning on and off. If you do not connect a reverse diode to the relay, the surge voltage will cause damage to the electric circuit of the controller. To reduce this surge, it is recommended to connect a reverse diode between the devices.
Output Connection Connect the 10-pin and 7-pin connectors of the controller as follows: EXIT Y Z [ \ ] CONTACT ^ _ ` AUX IN#1 lzj W lu{ EXIT EXIT BUTTON INSTALLATION AND EXTERNAL CONNECTION X DOOR CONTACT CHIME +12V i GND zzhTzYWWW GND ALARM RELAY COM DOOR RELAY COM DOOR RELAY NO Cathode Anode PIR SENSOR ALARM RELAY NO CHIME BELL +12V 1N4004~1N4007 or equiv.
installation and external connection EXTERNAL READER CONNECTION X Y Z [ \ ] ^ _ ` lzj W lu{ Wiegand DATA0(Pink) Wiegand DATA0(Sky blue) i zzhTzYWWW 검은색- 빨간색+ GND (+) DC+12V (-) - Proximity Reader Connection 1. Connect the DC 12V(+) of the power supply unit to the plus (+) line of the reader. 2. Connect the GND(-) line of the power supply unit to the minus (-) line of the reader. 3. Connect the Wiegand data input line 0 of the proximity reader to the purple line. 4.
initialization BASIC OPERATIONS Initial Status While the product is working normally, the orange LED indicator blinks every one second. When reading a registered card, it opens the door with the melody. t Gj X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW Exit Button Operation If you press the Exit button, the door will be opened. EXIT Predefined Operation for an Unregistered Card When reading an unregistered card, it produces an alarm with the melody for two seconds.
initialization WIEGAND OUTPUT SETUP You can transfer data of the card read by SSA-S2000 in the 26-bit Wiegand output format. Enabling this function will disable the TTL output and the chime bell sound. 1. To enable the 26-bit Wiegand output, you must manipulate the switch panel (SW1 and SW2) on the rear of the product. 2. See the table below to make adjustment as needed.
FORCED INITIALIZATION WITH EXTERNAL LINE 2. When the initialization is completed, 3 LED indicators are blinking with a beep. 12V X Y Z [ \ ] ^ _ ` lzj W lu{ GND Green Orange with white stripes i zzhTzYWWW Connect (Shortcircuit) 3. Restore the connection of the two lines back to their original state. HARDWARE FORCIBLE INITIALIZATION This is to initialize the product forcibly by disassembling it.
reader mode setup - You can specify the operation mode for the device. - Once a mode is specified, it will not switch until you perform the initialization. - You must keep the Master Card in safe for later use as it is required for your change to the device settings. - If progression is halted for more than one minute during any of the following processes, the operation mode of the reader will return to the previous state. READER MODE SETUP (RF ONLY) No Master Card or Master PIN is ever registered.
READER MODE SETUP (RF + P/W) No Master Card or Master PIN is ever registered. If you remember the Master Card or the Master PIN was registered, initialize the product and try again. • No flashing of the 3 indicators denotes that the reader mode is already specified. 2. Press Button 0 and Button 2 in sequence and press ENT . X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW 3. Present a card that you want to register as the Master Card to the device.
reader mode setup READER MODE SETUP (RF/PIN COMBINATION MODE) No Master Card or Master PIN is ever registered. If you remember the Master Card or the Master PIN was registered, initialize the product and try again. 1. When you turn on the product, all of the 3 LED indicators will flash with a beep. • No flashing of the 3 indicators denotes that the reader mode is already specified. X Y Z [ \ ] ^ _ ` lzj W lu{ i 2. Press Button 0 and Button 5 zzhTzYWWW in sequence and press ENT . 3.
user management TO REGISTER CARDS IN RF ONLY MODE Ensure that you must have registered the Master Card and the device is specified in RF ONLY mode. 1. Present the Master Card to the device. When the mode is specified, only the green LED indicator flashes. 3. Present a card to the device, it will be registered with a beep. Repeat this step if you want to register multiple cards. X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW 4.
user management TO REGISTER CARDS IN PIN MODE Ensure that you must have registered the Master Card and the device is specified in PIN mode. 1. Enter the Master PIN number and press ENT . When the mode is specified, only the green LED indicator flashes. 2. Press Button 1 and Button 3 in sequence and press ENT . When the mode is specified, only the green LED indicator flashes. X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW 3.
TO DELETE A REGISTERED CARD OR PIN NUMBER Ensure that you must have registered the Master Card or the Master PIN number and the device is specified in a certain mode. This is applicable in all modes. and Button 4 Gj t 2. Press Button 1 in sequence and press . When the device enters Standby, only the red LED indicator flashes. ENT X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW 3. Present a card or PIN number to delete.
basic setup DURESS ALARM If you are forced to open the door under the control of a criminal such as a robber, enter the predefined password with the number of your registered card (or PIN), which outputs the emergency TTL signal. 1. Present the Master Card to the device. 2. Press Button 2 and Button 9 in sequence and press ENT . . Gj t 3. Enter the two-digit Duress code and press ENT • The default code is set to “00”.
TO SPECIFY THE KEYPAD INPUT SUSPENSION TIME IF THE RETRY COUNT WITH AN UNREGISTERED ID EXCEEDS THE LIMIT 2. Press Button 6 and Button 0 in sequence and press ENT . ENT Gj t 3. Enter the two-digit keypad input suspension time (unit: minute) and press . X Y Z [ \ ] ^ _ ` lzj W lu{ i • The default is set to “01”. You can specify a time from 01 to 99 minutes.
basic setup TO SPECIFY THE OPERATION TIME OF THE DOOR CONTACT SENSOR The Door Contact sensor detects the opening of the door. If the door is forcibly opened by an unregistered user, the Door Contact Sensor will perform the predefined alarm operation after the set time. (For setting the alarm operation time, refer to the alarm output for an input error of the Door Contact Sensor on page 31.) 1. Present the Master Card to the device. ENT 3. Enter the two-digit operation time (unit: second) and press ENT . .
TO SPECIFY THE ALARM OUTPUT PORT FOR THE DISMANTLED DEVICE Specify the alarm type for the dismantled device. The alarm rings from the dismantlement of the device to the authentication of the Master Card or a registered card. 1. Present the Master Card to the device. ENT . Gj t 3. Provide the alarm output port and press ENT . X Y Z [ \ ] ^ _ ` lzj W lu{ i • The default is set to “02” (alarm). For the alarm output port settings, refer to the output port table on page 29.
basic setup TO SET OR RELEASE THE QUICK MODE The QUICK mode is applicable to RF ONLY mode (01) and PIN ONLY mode (03) and RF/PIN combination mode (05), which enables you to open the door by simply pressing ENT without the need of the PIN number. (This is useful for the normal business hours when the door entries and exits occur frequently.) 1. Present the Master Card to the device. 2. Press Button 4 and Button 3 in sequence and press ENT .
I/O time setup ❖ Output Port Setting Table You must specify the port settings using whatever combination of the followings if you want the device to operate in Secure mode or normal + Secure mode.
I/O time setup TO SPECIFY THE OUTPUT TIME IF THE CARD IS NOT AUTHENTICATED You can specify the output time if an unregistered card or PIN number fails in getting authenticated. 1. Present the Master Card to the device. 2. Press Button 2 twice and press ENT . • If you want the alarm relay alone to operate in normal and Secure modes for an unauthenticated card, select the < 5 2 > buttons and press ENT . 4. Enter the two-digit door relay output time and press 5.
TO SPECIFY THE ALARM OUTPUT FOR AN INPUT ERROR OF THE DOOR CONTACT SENSOR You can specify the output port and operation time if an error occurs from the Door Contact Sensor. You must have specified the operation time of the Door Contact Sensor. (Refer to “To specify the operation time of the Door Contact Sensor” on page 26.) 2. Press Button 2 and Button 4 in sequence and press ENT .
I/O time setup TO SPECIFY THE ALARM OPERATION TIME FOR AUX 2 1. Present the Master Card to the device. 2. Press Button 2 and Button 6 in sequence and press ENT . 4. Enter the two-digit door relay output time and press 6. Enter the two-digit TTL relay output time and press . ENT ENT Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW . ENT 5. Enter the two-digit alarm relay output time and press Gj t 3. Refer to the output port table on page 29 and specify a desired output mode.
TO ACTIVATE OR DEACTIVATE THE DOOR RELAY BY THE DOOR CONTACT SENSOR You can set the Door Contact Sensor to control the door lock. This is to allow the Door Contact Sensor to control the door relay where the sensor keeps the door relay active from the normal opening of the door to its closing. This is useful when the door stays open with just one authentication. 2. Press Button 4 and Button 7 in sequence and press ENT . The default is set to “disabled”.
advanced setting TO SPECIFY THE TTL OUTPUT OPERATION MODE This is to switch the TTL output from LOW (0V) to HIGH (5V) when it is activated. 1. Present the Master Card to the device. 2. Press Button 7 and Button 1 in sequence and press < 7 M 2 > buttons and press ENT . Gj t • To release the setting, repeat Step 1 above, select the ENT . X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW The default is set to “switch from HIGH(5V) to LOW(0V)”.
TO SPECIFY THE CHIME BELL OPERATION TIME You can specify the chime bell operation time. 1. Present the Master Card to the device. ENT . Gj t 3. Specify the two-digit operation time (unit: second) and press M Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW . ENT The default is set to “05” second. You can specify a time from 00 to 99 seconds.
advanced setting TO SPECIFY THE INPUT MODE FOR AUX 2 You can specify an operation for the auxiliary port 2 when it switches from LOW (0V) to HIGH (5V). 1. Present the Master Card to the device. 2. Press Button 6 and Button 3 in sequence and press . 4 > buttons and press ENT . Gj t • To release the setting, press the < 6 ENT X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW M The default is set to “switch from HIGH(5V) to LOW(0V)”.
TO SPECIFY THE INPUT MODE FOR THE EXIT BUTTON You can specify an operation for the Exit button when it switches from LOW (0V) to HIGH (5V). 1. Present the Master Card to the device. ENT . t ENT . M 8 > buttons and press Gj • To release the setting, press the < 6 Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW buttons and press The default is set to “switch from HIGH(5V) to LOW(0V)”.
additional features MUTE You can mute the keypad tone or melody in normal operation. 1. Present the Master Card to the device. ENT . t 2. Press Button 5 and Button 1 in sequence and press Gj M • To release the setting, repeat Step 1 above, select the < 5 2 > buttons and press ENT . X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW By default, it is set to “enabled”.
TO CHECK THE OUTPUT SPECIFIED FOR A REGISTERED CARD USER You can check the output setting that you specified in “To specify the output time if the card is authenticated”. (See page 29.) 1. Present the Master Card to the device. ENT .
additional features TO CHECK THE OUTPUT SPECIFIED FOR THE DOOR CONTACT SENSOR ALARM You can check the output setting that you specified in “To specify the alarm output for an input error of the Door contact Sensor”. (See page 31.) 1. Present the Master Card to the device. 2. Press Button 3 and Button 4 in sequence and press ENT .
TO CHECK THE OUTPUT SPECIFIED FOR AUX 2 You can check the output setting that you specified in “To specify the alarm operation time for AUX 2”. (See page 32.) 1. Present the Master Card to the device. ENT . Gj t X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW X Y Z [ \ ] ^ _ ` lzj W lu{ i zzhTzYWWW TO CHECK THE OUTPUT SPECIFIED FOR AUX 3 You can check the output setting that you specified in “To specify the alarm operation time for AUX 3”. (See page 32.) 1.
other information INITIAL VALUES This product operates in the following initial values: For changing the settings or registering/deleting the user card, refer to the applicable section in this document. 1) Entry permitted for a registered card - The door control relay operates for 3 seconds. - The green LED indicator flashes for 3 seconds. 2) Entry denied for an unregistered card - The alarm relay operates for 2 seconds. - The red LED indicator flashes for 2 seconds.
FUNCTION CODES NO.
other information NO.
troubleshooting TROUBLESHOOTING If the product does not work properly, please check the followings before contacting us. If the trouble persists, please contact the SAMSUNG Customer Service near you. Problem Action 1) Check if the product is installed properly and works normally. - In the initial setup of the product or after it is initialized Set the operation mode and register the Master card and user cards as usual because the product is in the initial state.
troubleshooting Problem I can not register an additional user card (or PIN). 46_ Troubleshooting Action 1) Check if the product is installed properly and works normally. - In the initial setup of the product or after it is initialized Set the operation mode and register the Master card and user cards as usual because the product is in the initial state.
Problem Action Check the operation status of the product 1) Check if the product works properly. - If the product operates normally (and you have the Master Card or the PIN number) c If you have the card to delete √ Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) √ Enter the command to delete the user: 14 + ENT √ Enter another card to delete (if you have multiple cards to delete) √ Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) + ENT) d If you have lost the card to delete.
troubleshooting Problem Action SSA-S2000 can recognize a presented RF card but can not recognize the RF card number using the keypad. 1) The Exit button does not work at all. 1) 48_ Troubleshooting Check if the buzzer sounds when you press a key.
Problem The external reader can the RF card but the RF card data will not be transferred to SSA-S2000 or irrelevant data is transferred. Action 1) 2) Check if the external reader is connected to SSA-S2000 properly. Check if the external reader works normally. - Check if there occurs a noise on the connection cable between the external reader and SSAS2000. c If you have to use a measuring device such as an oscilloscope or a multimeter, please consult with a qualified technician.
product specifications PRODUCT SPECIFICATIONS Item SSA-S2000 User 512 Users Power / Current DC 12V / Max.110mA Reader Port External Reder Port 1ea : 26bit Wiegand for Exit Reading Time (Card) 30ms Door Open Time 00~99 Sec. (Default 3Sec.) Input Port 5ea : Exit Button, Door Sensor, Aux#1, #2, #3 2ea : 2 Form-C Relay Output (COM, NO, NC) / DC12~18V, Rating Max.2A Output Port 1ea : Chime Bell Output / DC5V, Rating Max.500mA 1ea : TTL Output / DC5V, Rating Max.
Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life.