0X Day & Night PTZ Dome Camera SPD-1000 User’s Manual Thank you for purchasing a SAMSUNG CCD CAMERA. Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. SALES NETWORK • SAMSUNG TECHWIN CO., LTD. 145-3, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-120, Korea TEL : +82-31-740-8151~8158 FAX : +82-31-740-8145 • SAMSUNG OPTO-ELECTRONICS UK, LTD.
The lightning flash with an arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Features 10X Zoom Lens with Auto-Focus Function The 10X zoom lens having Auto-focus function magnifies the image up to 100 times when used with the digital 10X zoom function. Various Auto Surveillances *Individual Preset Saving Modes 12 camera adjustment functions can be saved independently in each Preset menu to provide optimum images. *Various Protocols 9 different makersí protocols are supported: Samsung Techwin, Pelco, Samsung Electronics, Panasonic, Vicon and Honeywell etc.
Contents Precautions Part Names and Functions Body Main Body Port Block Cable Connection Camera Initial Setting 8 10 10 10 11 12 Functional Description 31 OSD Menu Organization PTZ Camera User Menu Settings 1. Camera Settings 2. Sequence Setting 3. P/T Setting 4. OSD Setting 5. Alarm Setting 6. Initialize 7.
Precautions If any unusual odors or smoke comes from the camera, stop using the product. Experienced and skilled technicians have to install this product. Unqualified and personal installation may cause fire or electric shock. Contact the dealer for installation. Do not install the product under humid conditions or near flammable or explosive gases. It may cause fire. Install the product in a place strong enough to hold it. It may cause failure, electric shock or fire. The product may fall.
Part Names and Functions Body Cable Connection Main Body Port Block (Rear panel) Power Input Jack Camera ID Setting Switch Communication Protocols, Transmission Mode,Termination Setting Switch Controller and Alarm Input/Output Connection Terminal Auxiliary Video Terminal 10 11
Part Names and Functions Camera Initial Settings Setting Baud Rate Based on DVR Model Setting Communications Protocol Use the SW2 #1~#5 of installation bracket to set the communications protocol. Rear panel Number Protocol Samsung Samsung Pelco-D Pelco-D Pelco-P Pelco-P Samsung Elec. Samsung Elec.
Part Names and Functions Setting RS-485 Termination Set the termination using the ON/OFF of #7~#8 of the Rear Panel SW2. Rear panel Number Location of Camera Connection Termination of Longest Path On the Path SW2 - #7 ON OFF SW2 - #8 ON OFF Notes • Factory Setting: OFF • When you set up, refer to rear panel number(Ignore, DIP SWITCH number). Setting Camera ID Switch Set the Camera ID using the ON/OFF of #1~#8 of the Rear Panel SW1. Notes • Factory Setting: ID=001 ID=0, 160. 175 is cannot be used.
Part Names and Functions Camera ID 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 SW1-#1 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF SW1-#2 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON O
Part Names and Functions Camera ID 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 SW1-#1 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON SW1-#2 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
Part Names and Functions Camera ID 250 251 252 253 254 255 SW1-#1 ON ON ON ON ON ON SW1-#2 ON ON ON ON ON ON SW1-#3 ON ON ON ON ON ON SW1-#4 ON ON ON ON ON ON SW1-#5 ON ON ON ON ON ON SW1-#6 OFF OFF ON ON ON ON SW1-#7 ON ON OFF OFF ON ON SW1-#8 OFF ON OFF ON OFF ON Auxiliary Video Out Port When the product is installed in a place where video signal connection through the BNC port is unavailable, you can connect a video cable using the Auxiliary Video Out Port.
Installation Components and Accessories ENGLISH Accessories power adapter (DC 12V, Peak 4A) BNC auxiliary cable User s Manual installation cover installation template Preparation for Cable To install and use the SPD-1000, the following cables should be used. • Power Adapter Cable The cable connected to the power input terminal of SPD-1000 is shown below with a rated voltage of DC 12V 4A.
Installation Cable Connection Installation of SPD-1000 1. First, connect one end of the BNC video cable connector to the Video Output Terminal. Monitor In Terminal 2. Next, connect the other end of the connector to the Video Input Terminal of the monitor. Video Out Terminal Monitor DATA BOX Controller Connection Terminal 3. Connect the Controller Connection Terminal of SPD-1000 and the external Controller.
Installation Installing the SPD-1000 on a Ceiling 1. Prepare the accessories in the camera box (power adapter, installation template, BNC auxiliary cable, 1 loose-proof screw, 3 installation bracket fixing screws, 2 installation brackets, installation cover) and a tool for making a hole in the ceiling. 3.
Installation Installing the SPD-1000 Wall Mount 1. Prepare the accessories in the camera box (power adapter, BNC auxiliary cable, 1 loose-proof screw, 2 installation brackets, installation cover) and the wall mount (STB-280PW or STB-230PW) and 3 installation bracket fixing screws in the mount packaging box. power adapter(DC 12V, Peak 4A) 1 looseproof screw BNC auxiliary cable installation cover STB-280PW 2.
Functional Description Installation 5. To complete installation, rotate the installation cover along the groove of the ceiling attachment bracket, and fix it. Wall OSD Menu Organization PTZ camera can be set up on the OSD (On Screen Display) menu displayed on the video monitor by the camera controller. The joystick operations in the OSD menu are as follows. In addition, sending control codes to the camera from the PC can also use the camera functions.
Functional Description P1 P2 Preset Swign SEQ Group SEQ Sequence Setting Tour SEQ PTZ Trace Auto Run Power On Resume Pan Limit Tilt Limit P3 P4 Setting Edit Execute Clear Status Pan Swing Setting Execute Clear Tilt Swing Setting Execute Clear P/T Swing Setting Execute Clear Group1 Setting Execute Clear Group2 Setting Execute Clear Group3 Setting Execute Clear Group4 Setting Execute Clear Group5 Setting Execute Clear Group6 Setting Execute Clear Setting Execute Clear Trace1 Replay Memorize Trace2 Repl
Functional Description Symbol Description 1. Motion Stabilization Stand-by Operation - “D” symbol is flashing on the right top of the screen. 2. Alarm Input #1, 2 Sensor Operation - “ ”, “ ” symbols are flashing on the right top of the screen. 3. Alarm Output Operation - Symbols are flashing on the right top of the screen. 4. Motion Detect Operation - “Man Icon” is flashing on the right top of the screen. 5.
Functional Description Exposure White Balance The White Balance function corrects the abnormal white colour into the normal white colour under any colour temperature lighting. Select the mode among ATW, AWC and Manual. ATW is selected by default. Camera Setting Focus White Balance Exposure Back Light AGC SSNR Day & Night Others ATW(O) OFF NORMAL LOW COLOR WB Mode ATW: Balances the colour automatically depending on the source of light from 1,800~10,500K colour temperature.
Functional Description Sens-Up Auto: The low light level of the night or dark condition is detected automatically and the bright and clear image can be maintained. Sens-Up Limit: Maximum accumulated magnification can be selected. Off: Sens-Up function is cancelled. Notes • As the accumulated magnification increases, the screen goes bright. But, the after image of the moving object also becomes larger and the optimum Auto Focus function may not work.
Functional Description Others Day & Night The darkness level is detected automatically under low light conditions such as at night or under dark light to keep the screen bright and clear.
Functional Description • Preset Menu Setting 1. Select the Preset item on the Sequence Setting Menu 2. Select the Setting item. 2) Sequence Setting • Sequence Setting Menu Sequence Setting Preset Preset Swing SEQ Group SEQ Tour SEQ PTZ Trace Auto Run Power On Resume OFF Setting Edit Execute Clear Status Preset : 12 items such as Pan/Tilt location, Zoom and Focus are selected among camera functions and they can be called for monitoring. Total 128 points can be preset.
Functional Description 6. If you select the Scene Adj. item, such items as Shutter, AGC, SSNR, Sens-Up, White Balance can be set up differently in every Preset item. Scene Adj. Shutter AGC SSNR Sens-Up White Balance [001] --Normal LOW AUTO ATW(OUT) Notes • In the White Balance setting of the individual Preset Scene Adj., the AWC selection is not available. Swing SEQ : Swing surveillance can be executed and set up and the data can be deleted.
Functional Description PTZ Trace : Maximum 4 patterns of the manual operation paths (for Pan, Tilt, Zoom and Focus) are memorized and replayed. Sequence Setting PTZ Trace Preset Swing SEQ Group SEQ Tour SEQ PTZ Trace Auto Run Power On Resume OFF Trace Trace Trace Trace 1 2 3 4 Replay : The manual operation paths are repeated and replayed. Stop key will stop the replay. * If the operation range is limited using Pan Limit and beyond the limited operation range are not possible.
Functional Description On/Off : It can be determined whether or not to activate the area mark. The activation becomes effective as soon as the position moves from the current area to other areas. Set up the OSD Setting as ON. If it is in OFF mode, this function does not work. Default setting is OFF. Tilt Limit : Moving range in the tilt direction can be limited.
Functional Description Digital Flip : When you operate the Tilt up to 100˚ limit using the joystick and keep it for a certain time, the image gets reversed automatically and the opposite Tilt area is seen. When you want to monitor the moving object under the camera, execute the Digital Flip function using the controller’s joystick. You can observe the moving object without reversing of the screen.
Functional Description Preset Number (Default setting is ON.) : Preset numbering is set up. Sequence Status (Default setting is ON.) : Display of the Sequence Group is set up.
Functional Description Language : The OSD can be displayed either in English (default setting) , Chinese, French, German, Italy and Spanish Main Menu OSD Setting Camera Setting Sequence Setting P/T Setting OSD Setting Alarm Setting Initialize Status Camera ID Camera Name Preset Number Preset Name Sequence Status Area Name PTZ Position Language ON ON OFF OFF ON English NC/NO/OFF : NC/NO/OFF can be selected depending on the alarm sensor. L/H (Priority) : Priority for the 2 alarm inputs is set up.
Functional Description MD Dwell Time : When was motion detection in each preset that have established motion detection function, it set time that keep relevant preset. For detailed settings of the Motion Detection for each Preset menu, see page 42 and 43.
Product Structure and Installation Product Structure Installation1 (Mini PTZ Dome Camera Control) 58 59
Specifications Product Structure and Installation Installation 2 (Mini PTZ Dome Camera Control) SPD-1000N SPD-1000P 1/4” Color Interline Transfer CCD. Imaging device NTSC PAL Total Number of Pixels 811(H) X 508(V) 795(H)X596(V) Valid Pixel 768(H) X 494(V) 752(H)X582(V) 15.734kHz 15.625kHz TV Horizontal Scan Frequency Vertical Scan Frequency 59.94Hz 50Hz Internal Sync Synchronization 1.
DECLARATION OF CONFORMITY Specifications SPD-1000N Vertical Rotation Speed SPD-1000P Manual: 0.5˚ - 50˚/s(64 levels) Preset: 0.5˚ - 100˚/s(64 levels) Vertical Minimum 0.02˚ Moving Angle Preset Position Max 128 points Area Masking Max 4 locations Alarm 2 Alarm Inputs 1 Alarm Outputs (Relay: NC/NO/COM, 0.