installation & connection
10_ installation & connection
Outdoor installation
When you install it outside of the building, please waterproof it with waterproof butyl rubber tape (can be
purchased in stores) so that water does not leak from the gap of the cable connected to the outside.
1. Connect to cables, such as I/O and audio.
2. Wrap the black cable jacket (Area A) and the cable connection
area with waterproof (butyl rubber) tape so that more than half of
the butyl rubber tape is overlapped.
J
`
If the cable jacket is not waterproofed properly, then it can directly cause
leakage. Make sure to protect the cable with a dense layer of taping.
`
Waterproof butyl tape is made of butyl rubber that can be stretched to
twice its normal length.
4. Insert the LAN cable into the large hole made by removing the
projected part of the rubber plug in step 1 above.
5. Remove the sheath with a cable cutter, and align the cables.
6. Connect the LAN cable with a LAN connector, and insert it into the
LAN tool.
7. Connect the finished cable to the Ethernet port.
Connecting the alarm and audio cable
1. Remove the rubber cover on the bottom side of the bottom cover
as shown in the figure below.
2. Insert the alarm/audio cable through the hole created by removing
the rubber cap in No. 1, and connect the cable to the alarm
terminal.
3. Align the cable so that it should not be damaged or jammed
when installing the camera.
4. Put the rubber cap located on the alarm/audio cable in the hole.
CAUTION : Be ware o f the
Rated Vo ltage and P olarit y
of the power conne ction.
123 45 678
1:LINE I N
2:GND
3:AUDI O O UT R
4:AUDI O O UT L
5:GND
6:ALAR M IN
7:ALAR M OU T
8:ALAR M OUT 2
CAUTION : Be ware o f the
Rated Vo ltage and P olari ty
of the power conne ction .
123 45 67 8
1:LIN E IN
2:GND
3:AUD IO OU T R
4:AUD IO OU T L
5:GND
6:ALA RM IN
7:ALA RM O UT
8:ALA RM OU T2
Camera
Camera
Camera
System
System
System
AA