Quick Start GUIDE COLDSTORE | CSTORE15-3U Version 3.0.
Contents A) Quick Start Guide Legends 3 B) Safety Instructions 3 C) Product Package Contents 4 D) Basic Requirements 4 E) System Overview 4 F) Chassis Mounting 4 G) System Connections 5 H) Disk Loading 5 I) Power Up Sequence 6 J) Front Panel Menu 6 K) COLDSTORE Set up and Maintenance Software - SITESCAPE 7 Installing SITESCAPE 7 Getting Connected 8 L) System Configuration 11 M) Disk Management – Adding & Removing Disks 13 N) Troubleshooting 13 No power 13 No
A) Quick Start Guide Legends The Information icon highlights particularly useful information or items which are very important to note when using or configuring the product. The Caution icon indicates possible actions or procedures which could prevent proper operation or cause a system malfunction and the associated text will explain how to avoid this.
Ensure that the product is securely held at all times as dropping the product will almost certainly damage it (possibly beyond repair) and more importantly, may cause severe personal injury, especially to hands and feet. Extreme caution is essential. Do not move the system once powered up. To do so may result in damage to the disks and potential loss of data. C) Product Package Contents Carefully unpack the package contents.
We highly recommend that the unit is mounted into a rack for normal operation. If rack-mounted, it is essential that the unit is mounted on a rack tray or shelf for support – it should not be mounted on the rack-mount lugs alone. We highly recommend that the unit is mounted in the rack (or if not to be rack mounted, placed in the desired location) before any disks are inserted. The unit is quite heavy when empty, but very heavy when fully populated with hard disks.
Carefully insert the loaded trays into the COLDSTORE unit, starting from the left (Disk Slot 1) and filling each slot in sequence with as many disks as required. The trays should be inserted as follows: With the tray level wide open, insert the tray into the slot taking care that the tray guide lines up with the disk cage runners.
Select IP Address 1 010.000.000.140 IP Address 1 corresponds to the ETH1 connection. Press Cancel at any time to move back up the menu hierarchy. Pressing Cancel three times will return to the default (general status) display. See the COLDSTORE User’s Guide for full details of the front panel menu system and control. K) COLDSTORE Set up and Maintenance Software - SITESCAPE SITESCAPE is a software application which works with all configurable Veracity network devices.
instructions from that software to allow installation of SITESCAPE. If successful, the Installation Setup Completed dialog is shown. Getting Connected i) Network with DHCP server By default, COLDSTORE has DHCP server support disabled. If DHCP server support on the COLDSTORE is enabled then, after powering up your COLDSTORE, the COLDSTORE will use the network settings assigned by the DHCP server on your network.
The first time you run SITESCAPE, the Authentication and server selector SITESCAPE dialog is shown. Click Yes if you want a user name and password to secure access to SITESCAPE in future, otherwise click No. Click Save. The SITESCAPE application main window is shown. 6 To find your COLDSTORE device on the network, click the Discovery link in the left-hand panel. The Discovery window is displayed in the right-hand panel. 7 Click Search.
d Click the Manual tab. The Discovery window shows an entry for the COLDSTORE. 9 Put a check in the checkbox next to the COLDSTORE entry. 10 Click Next. The Selected Devices window is shown. If the COLDSTORE entry shows a Credentials Required link, then proceed as follows: a Click Credentials Required. The Credentials dialog is shown. b Enter the username and password for the COLDSTORE. By default, the device username is admin and device password is admin. c Click Save.
12 Click Done. The My Site window is shown. If a COLDSTORE entry is shown, you have successfully added the COLDSTORE and it is ready for configuration. Skip to section L). If no COLDSTORE entry is shown, ensure that you selected the COLDSTORE in the Discovery window, specified correct credentials for the COLDSTORE in the Selected Devices window, that you clicked Add to site and were shown the Complete! confirmation window before you clicked Done.
4 Click Configure network settings. To show labels for the COLDSTORE configuration windows including Configure network settings click the … button. 5 Put a check in the checkbox next to the COLDSTORE entry. The Interface 1 IPV4 protocol and IPV6 protocol and Interface 2 IPV4 protocol and IPV6 protocol tabs will update with the current network settings for the selected COLDSTORE. The Interface 1 tab shows the network settings for ETH1 network connection. Interface 2 tab the ETH2 network connection.
sent to the COLDSTORE. The COLDSTORE will now automatically reboot and will have the network settings you specified. Continue as follows: a Wait until the Status LED of the COLDSTORE is flashing again. b On the COLDSTORE front panel menu, initiate a shutdown of the COLDSTORE. The LCD display will update to show the shutdown process. Wait until the LCD display shows the Power Off message. 11 c Power off the COLDSTORE.
Check the power cable fuse and if necessary replace the fuse or try a different power cable. Check that the wall socket is live by plugging another device into it. No disk If there are no disks present, COLDSTORE will not be able to operate. Please switch off the unit and add at least two, preferably three disks to the array as described above. A COLDSTORE in this state will not appear in SITESCAPE search results. Check the IP address of the unit as described in section J) above.