Specifications
13-306 | OWNER’S GUIDE
MODULE INPUT TYPE RANGES TEDS
BANDWIDTH BW
FILTERS LP / HP
ISOLATION ISO
OVERVOLTAGE
PROTECTION OP
DAQP-THERM
Thermocouple
(universal)
K, J, T, R, S, N, E, B, L, C, U
freely programmable within
the maximum range of the
selected thermocouple type,
internal linearization, internal
CJC
N/A
BW: 3 kHz
LP: 3Hz, 10 Hz, 30 Hz, 100
Hz, 300 Hz, 1 kHz
Butterworth or Bessel;
2nd, 4th, 6th, or 8th order
(programmable)
ISO: ±1000 Vrms
continuous
DAQP-MULTI
V
Thermocouple
(universal)
K, J, T, R, S, N, E, B, L, C, U
type, internal linearization,
freely programmable range,
internal CJC
Yes
BW: 3 kHz
LP: 3Hz, 10 Hz, 30 Hz, 100
Hz, 300 Hz, 1 kHz
Butterworth or Bessel;
2nd, 4th, 6th, or 8th order
programmable
ISO: 1000 Vrms
continuous (for
input, excitation and
TEDS interface)
RTD
Pt100, Pt200, Pt500,
Pt1000 and Pt2000 sensors,
programmable range (2-wire
and 4-wire only)
Voltage
10 ranges from ±5 mV to
± 5 V
Resistance
freely programmable range
from 1 Ω to 1 MΩ
Bridge (constant
current)
4-wire full bridge sensors,
13 ranges from ±0.5 to 5000
mV/mA
Frequency to Voltage Measurement
DAQP-FREQ-A
Frequency to
voltage
100, 1k, 5k, 20k, 100k and
200 kHz ranges;
Trigger level range 0 to 130 V,
Additional TTL output
(isolated pulse output of input
signal)
N/A
BW: 200 kHz
Selectable input and output
filters (range-dependent)
ISO: 350 Vrms
Output modules
DAQN-V-OUT
OUT
Analog output
1:1 output module, from 0 to
±10 V; Accuracy ±0.05 %
Connector choices: banana,
BNC, or 9-pin DSUB
connector
N/A BW: 400 Hz
ISO: CMV output to
input, continuous:
1500 VRMS max