User Manual
Table Of Contents
- overview
- outdoor vandal dome
- indoor vandal dome
- flush mount dome
- installation & connection
- network connection and setup
- Connecting the Camera Directly to Local Area Networking
- Connecting the Camera Directly to a DHCP Based DSL/Cable Modem
- Buttons used in IP Installer
- Static IP Setup
- Dynamic IP Setup
- Port Range Forward (Port Mapping) Setup
- Connecting to the Camera from a Shared Local PC
- Connecting to the Camera from a Remote PC via the Internet
- web viewer
- appendix
20_ indoor vandal dome
indoor vandal dome
2-3. Place the pipe on the mount plate.
2-4. Fix the mount plate using appropriate screws.
2-5. Pull out necessary cables among LAN/power/audio & alarm cables through the pipe.
Installation (camera case)
J
`
Use a cable bush compliant with the LAN cable to be connected.
-
Camera main: use a cable with the diameter of Ø5 to 6.5
-
Components: use a cable with the diameter of Ø5 to 8.5
[Installing LAN/power cables]
1-1. Pull off the extruded parts of the bush to be used.
1-2. Route the LAN cable through the big hole of the bush and connect to the LAN connector.
1-3. (When using the power) Route the power cable through the small hole of the bush and connect it to the
provided terminal block.
[Installing using pipe]
2-1. Attach the installation template and drill holes for screws and cables.
2-2. Separate the pipe cover of the mount plate by pressing its sides.