installationinstallation
Please take note of the followings before using this product.
• Do not use the product outdoor.
• Do not spill water or liquid in the connection part of the product.
• Do not impose the system to excessive shock or force.
• Do not pull out the power plug forcefully.
• Do not disassemble the product on your own.
• Do not exceed the rated input/output range.
• Use a certified power cord only.
• For the product with an input ground, use a grounded power plug.
M
` Depending on the hard disk configuration and the surrounding temperature, there may be some noise from the product.
CHECKING THE INSTALLATION ENVIRONMENT
This product is a top-notch security device that is equipped with a
high-capacity HDD and other key circuit boards.
Note that an excessive internal temperature of the product may
cause a system failure or a shortened product life (see the right
figure). Keep in mind the following instructions before installing the
product.
One Year: 24HR X 365 DAY =8,760 HR
Temperature
Unit: ºC
Life (Unit: HOURS)
[Figure 1]
When mounting the product on a rack, comply with the following instructions.
1. Please ensure that the rack inside is not sealed.
2. Please ensure the air is circulated through the inlet/outlet as shown in the picture.
3. If you pile up the products or other rack-mount devices as shown in figure 2, secure room for
ventilation or install a vent.
4. For natural air convection, place the inlet at the bottom of the rack and the outlet on top.
5. It is strongly recommended that a fan motor is installed at the inlet and the outlet for air
circulation.
(Please fit a filter at the inlet to screen dust or foreign substances.)
6. It is recommended to keep the temperature inside the rack or around the product at 25°C.
Rack Mount Instructions - The following or similar rack-mount instructions are included with the
installation instructions :
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of
air flow required for safe operation of the equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections to the
branch circuit (e.g. use of power strips).
[Figure 2]
INSTALLING THE RACK
Rack installation requirements and reference dimensions
Classification Requirements
Rack type 19-inch rack of EIA-310-D standard
POST count 4
POST distance Depth 800 mm
Dimensions of mounting flange
C
B
A
Product
Product
Product width
EIA-310-D standard mounting
flange
• Notable dimensions
Index Dimension
A 450 mm (17.717 inches) min.
B 465 mm (18.307 inches) nominal
C 483.4 mm (19.031 inches) min.
• Flange mounting holes (square holes are recommended for XRN-6410 series)
While EIA-310-D standard allows the mounting flange holes to be round, square, or tapped (threaded),
the XRN-6410 series is only designed to work with round or square holes, but not tapped holes.
• Square mounting holes
15.90 mm (0.625 inches)
15.90 mm (0.625 inches)
12.7 mm (0.50 inches)
9.5 mm (0.375 inches) Square
44.45 mm (1.750 inches)
15.90 mm (0.625 inches)
15.90 mm (0.625 inches)
12.7 mm (0.50 inches)