In order to calibrate the reader for 32.5 dBm, use the following table to look-up a
corresponding index number to write to the reader. As shown in the following table,
32.5 dBm corresponds to an index of 0e.
To write the index of “0e” to the reader, perform the following:
1. To set the reader for 32.5 dBm at the port 1 antenna connector, execute the
following the following CHUMP command:
}cw,d:TP0,b:0e000000,f:1!
where:
The digit following TP is the port number minus 1.
The left two digits of the eight bit word are the index number (0e).
2. Connect a power meter connected directly to port 1. The meter should read 32.5
dBm. The power meter should read 30 dBm if connected to the end of the 15
foot cable.
3. Repeat this procedure for each port.
Index Pout
(dBm) (W)
Index Pout
(dBm) (W)
Index Pout
(dBm) (mW)
Index Pout
(dBm) (mW)
Index Pout
(dBm) (mW)
00 27** 0.5 14 31 1.26 28 26 398 3c 21 126 50 16 40
02 34.7 2.95 16 30.5 1.12 2a 25.5 355 3e 20.5 112 52 15.5 35
04 34.3 2.69 18 30 1 2c 25 316 40 20 100 54 15 32
06 34 2.51 1a 29.5 0.89 2e 24.5 282 42 19.5 89 56 14.5 28
08 33.7 2.34 1c 29 0.79 30 24 251 44 19 79 58 14 25
0a 33.3 2.14 1e 28.5 0.71 32 23.5 224 46 18.5 71 5a 13.5 22
0c 33 2 20 28 0.63 34 23 200 48 18 63 5c 13 20
0e 32.5 1.78 22 27.5 0.562 36 22.5 178 4a 17.5 56 5e 12.5 18
10 32 1.58 24 27 0.501 38 22 158 4c 17 50 60 12 16
12 31.5 1.41 26 26.5 0.447 3a 21.5 141 4e 16.5 45
** Index 00 is no longer valid, the output power is defaulted to index 24, or 500 mW (27 dBm).