User's Manual

Table Of Contents
Installation
7
Reader Mechanical Installation
The MP9310 is designed for installation with the enclosure. The following
instructions provide the information to install your UHF reader.
As shown in Figure 5, enclosure is provided with four M3-6 threaded inserts for
horizontal or vertical installation. If the threaded inserts are not used, mounting
brackets may be required. Contact SAMSys for additional mounting instructions.
Figure 5–MP9310 Enclosure Dimensions
Reader Electrical Installation
As shown in Figure 6, the MP9310 is equipped with a 26-post header (2x13, 0.05"
center, 0.016"sq post
) for power, ground, and communication connections. The
antenna connection is provided by a right-angle, bulk-head mount SMA connector.
An optional Ethernet connector provides TCP/IP connectivity.
Figure 6–MP9310 System Connector and Optional Ethernet Port
Refer to Chapter 6 - Specifications for detailed information on the DC Power, RS-
232, Digital I/O, and optional Ethernet connections.
7.943 in
0
.854 in (w/o Ethernet)
1
.300 in (w/ Ethernet)
7.303 in
2.176 in
2.756
in
M3-6 (Typ)
Ethernet (optional)
System Connector [SCON1]
125
26 2
System Connector