12
MP9310 Power Up and Initialization
When the power supply is connected, the MP9310 starts an internal initialization
sequence.
After the initialization sequence, the reader activates the RF field and, depending
on the configuration, begins transmitting read detect (Rd) commands at the
specified frequency.
Setting the RF Mode
The MP9310 is factory configured for continuous RF scanning or “auto-read” mode. This
mode is equivalent to mode selected by the
Auto Read function key on the RF Command
Suite
Command interface window.
If desired, you can reconfigure the reader for Polled RF mode (reader activates the
transmit carrier and waits for host to send a read command). Select the
Polled Read
function key to activate Polled RF mode.
To halt the Auto Read or Polled Read mode, press the
RF Off function key.
Selecting Tag Protocols
The MP9310 is factory configured with only those protocols selected by the user. Once
protocols are activated, the
Command tab function keys can be used to select the protocol.
These function keys are programmed with specific command sequences required by the
reader to select a particular protocol. To select a specific protocol, perform the following:
1. Select the
Command interface window.
2. Select
Function Set 2 or 3 and locate the required protocol.
3. Press the function key to select the protocol.
4. To view the command sequence performed by this function, hold the mouse pointer
over the key or right click while holding the mouse pointer over the key and select
Edit Macro.
5. Do not change the command sequnce unless you are experienced using SAMSys
CHUMP commands to configure readers.