Operation
17
Modifying Tags
RF Command Suite can be used to modify previously programmed tag data. To
modify tags, perform the following:
1. Select the Tag Summary interface and right-click on the tag.
Figure 14–Select Tag to Modify
2. Select Modify Tag. The tag data window is displayed.
Figure 15–Modify Tag Option
3. Select the Address from the pull-down.
4. Enter the data
Length and actual Data for the specific address
5. Select if
ASCII data and whether or not there is a Single tag in field.
6. After all data and parameters are entered, press Write .
7. Repeat for each address.
Resetting the MP9310
To reset the MP9310, drive the reset line low for 3 ms. Refer to Chapter 5 -
Specifications for detailed information for location of the reset pins on the system
connector (SCON1).