User's Manual

Table Of Contents
Specifications
25
Antenna Requirements
The antennas used with this transmitter must be professionally installed in a
manner which guarantees compliance with all local laws and regulations.
Note 1: To comply with EN 302 208, the installer must use an antenna whose beamwidth shall be
less than or equal to 90 degrees for transmit ERP levels less than or equal to 500 mW. For
transmissions above 500mW and less than or equal to 2W, a minimum antenna beamwidth
of 70 degrees is required.
Note 2: In accordance with local regulation.
FCC Radiation Exposure Statement
The antennas used for this transmitter must be installed to provide a separation distance
of at least 20 cm from all persons and must not be co-located or operating in conjunction
with any other antenna or transmitter. The spacing between users and the antenna must
be a minimum of 20 cm.
Caution
To prevent reader damage, the RF port must be properly terminated with a 50 Ohm load
or a functional UHF RFID antenna before power up. Never power up the reader unless the
loads or antennas are connected. Always power down the reader before removing an
antenna or load from an RF port.
Antenna Parameter North American (FCC) European Union (ETSI)
302-208 300-220
Frequency 902 to 926 MHz 865 to 868 MHz 869.525 MHz
Polarization Circular or Polarized Circular or Polarized Circular or Polarized
Impedance 50 Ohms 50 Ohms 50 Ohms
VSWR, maximum 1.25:1 1.25:1 1.25:1
Antenna gain 9 dBi, Max See Note 1 See Note 2