Programming Instruction

Dust Cyclone- Remote control panel function
SF-H01A
2022/01 V1.0
1
PROGRAMMING INSTRUCTION
FOR HANDHELD REMOTE CONTROL-ZF1530-K4S
Button A : ON button. Turns the cyclone ON, the Power indicator light will
illuminate.
Button B: OFF button. Turns the cyclone off, the Power indicator light will go off.
Button C: CLEAN button. Starts to clean cartridge filter, rotate clockwise (10s) and
anti-clockwise (10s) for a cycle.
Button D: RESET button. Press SW1 or Reset button from remote switch until you
hear two beeps. Press the RESET Button from handheld remote
control until you hear three beeps to complete the set up.
Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment. This
equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency
B: OFF button
A: ON button
D: Reset button
C: CLEAN button