6.2 Error Posting
The following table summarizes the valid status and error value for all the ATA Command set.
Table 6-7 Error and Status Register
Error Register Status Register
Command BBK UNC IDNF ABRT AMNF DRDY DWF DSC CORR ERR
Check Power Mode V V V V V
Execute Drive Diagnostic* V V V
Erase Sector(s) V V V V V V V V
Format Track V V V V V V V
Identify Drive V V V V V
Idle V V V V V
Idle Immediate V V V V V
Initialize Drive Parameters V V V
Read Buffer V V V V V
Read Multiple V V V V V V V V V V
Read Long Sector V V V V V V V V
Read Sector(s) V V V V V V V V V V
Read Verify Sectors V V V V V V V V V V
Recalibrate V V V V V
Request Sense V V V V
Seek V V V V V V
Set Features V V V V V
Set Multiple Mode V V V V V
Set Sleep Mode V V V V V
Stand By V V V V V
Stand By Immediate V V V V V
Translate Sector V V V V V V V V
Wear Level V V V V V V V V V
Write Buffer V V V V V
Write Long Sector V V V V V V V V
Write Multiple V V V V V V V V
Write Multiple w/o Erase V V V V V V V V
Write Sector(s) V V V V V V V V
Write Sector(s) w/o Erase V V V V V V V V
Write Verify Sector(s) V V V V V V V V
Invalid Command Code V V V V V
V = valid on this command * See Table 6-2