4. Factory AsteRx2/AsteRx2e receiver Settings
The instructions below should be used to reconfigure an APS-3 back to ALTUS
Default. This is the #1 method for resolving problems with the APS-3’s operation, and
should always be executed before contacting ALTUS support.
Reconfiguring the APS-3 back to ALTUS Default sets the unit as a Rover, Message
Type: RTCM v3.1, Logged Data Type: SBF. The two ways of accomplishing factory
settings are:
1) Upload appropriate
[1]
ALTUS default script using RxControl
2) Typing the commands in line-by-line.
[1]
The APS-3 model is determined by the serial number found on the bottom of
the receiver. Serial numbers in the 10000 series are classified as APS-3.
Serial numbers in the 20000 series are classified as APS-3 V2.
4.1. Uploading a script/text file using RxControl
A text file with factory reset commands is included on the CD shipped with each new
APS-3 unit. The file can also be downloaded from the ALTUS website (linked):
APS-3 (10XXX): APS-3 Default Config.txt
APS-3 V2 (2XXXX): APS-3 V2 Default Config.txt
4.1.1. From the RxControl File menu, select “Upload script”.
Figure 10: Upload Script