Specification

CONNECTIONS
SANIPLUS Macerator
The Saniplus is a 1/2 HP pump system used to install a complete bathroom up to 15 feet below the sewer line,
or even up to 150 feet away from a soil stack. It incorporates a macerating system which can handle human
waste and toilet paper in residential applications. The blade is made out of a hardened stainless-steel material
which eliminates the need for any service or replacement.
Discharges the waste through a 3 4 or 1” rigid pipe. A non-return valve is included on the discharge
elbow assembly provided with the system. This elbow can be rotated 360 degrees depending on the
discharge installation.
Has been designed with a 1–12” vent connection on the top of the lid. All plumbing codes require
connection to a vent system. Please note that the vent system should be a two-way air vent as air needs
to freely flow both ways. Note: The use of mechanical vents, air admittance valves or similar devices is
not permitted.
Must be connected to Saniflo’s 1.28 GPF / 4.8 LPF rear discharge toilet. These toilets come in round and
elongated (ADA compliant) models. More technical information on page 6.
Will also discharge gray water from any sink, bath/shower or urinal. The wastewater will drain into the
system via two 2” inlets with built-in check valves on either side of the housing. Note that when adding
a bathtub/shower, the base should be raised up by a minimum of 6” off the floor.
APPLICATION
RESIDENTIAL
INSTALLATION BEHIND THE WALL
ASME A112.3.4
INSTALLATION BEHIND THE TOILET
Example of installation. Follow local plumbing codes for actual install. Example of installation. Follow local plumbing codes for actual install.
TOILET
SHOWER
SINK
BATHTUB
SANIPLUS • Part N
O
002
PUMPING DISTANCE
15 Ft
150 Ft
Toilet Tank
(Part N
o
005)
Insulated 1.28 GPF / 4.8 LPF toilet tank equipped with all internal
valves. For more information, please turn to page 6.
Round/Elongated Bowl
(Part N
o
083 or 087)
Rear discharge toilet with 163/4” seating height (Elongated
bowl is ADA compliant). For more information, please turn to
page 6.
Extension Pipe
(Part N
o
030)
18” long PVC pipe with internal gasket used to hide the pump
behind the wall. For more information, please turn to page 51.
Saniplus
(Part N
o
002)
1/2 HP macerating pump for residential applications. Ideal for
creating a complete bathroom in a basement, attic, garage, pool
house, etc.
8