Installation Instructions

AVERTISSEMENT
SANISTAR
®
is a wall hung toilet with an inter -
nal macerator/pump to which you can also
connect a washbasin.
The SANISTAR
®
can only be installed with the
special support bracket supplied.
SANISTAR
®
is for use in a domestic environ -
ment.
Installed and used correctly, SANISTAR
®
will
give you reliable and consistent service.
"WARNING" This is a general warning that
failure to follow instructions could result in poor
functioning of the unit.
PRINCIPLES OF OPERATION
SANISTAR
®
is controlled by an electronic
program with two functions.
• Pressing the push button on the bowl
activates the flush cycle. Depending upon
the discharge pipe configuration, the
macerating/pump cycle may take as long as
25 seconds.
• The pump cycle cleans the washbasin
waste. This is an automatic operation that
will activate as long as water from the
washbasin enters the unit.
1
LIST OF ACCESSORIES SUPPLIED :
see drawing 2
2
DIMENSIONS
:
see drawing 3
3
TECHNICAL DATA
Application 1 WC + 1 washbasin
Maximum vertical pumping 9 feet
Voltage 120 V
Frequency 60 Hz
Normal power rating 960 W
Maximum current consumption 9 A
Maximum water temperature 100°F
Electric class I
Degree of protection IP44
Net weight (with frame) 62 Ibs
Horse power 0.7 HP
WARNING: Only installations conforming to
the above specifications are acceptable.
4
PERFORMANCE CURVE
:
see drawing 5
5
VERTICAL/HORIZONTAL
PUMPING COMBINATIONS
:
see drawing 6
6
INSTALLATION
PREPARATIONS
WARNING: Before proceeding with the
installation of SANISTAR
®
, ensure that the
wall is sufficiently robust to support the unit.
(Each fastening should have a
tensile strength of 120 kg (264lb)).
7
HANGING THE BOWL ONTO
THE SUPPORT FRAME
1 -
Separate the bowl and template from
the frame (shipped together for transit
purpose).
- Assemble the threaded rods /with
nuts /and washers as per
drawing .
- Adjust nut on threaded rod to 2-inches
(50 mm) + x the wall thickness (e.g. wall
board plus tiles etc.). See drawing .
4 -
Adjust the lateral spacing of the rods so
that they line up with the holes in toilet.
5 -
Tighten the nuts fully.
6 -
Fit the plastic sleeves/inserts onto
the treaded rods and tape them down
temporarily. (They protect the ceramic
from the metal threads).
SETTING THE HEIGHT OF THE
SUPPORT FRAME
- Place the frame against the wall.
- Adjust to a comfortable height using the
vertical threaded feet. (See drawing ).
(Note ADA requirements is minimum
17-inches from floor to to top of toilet
seat. Adjust the feet from floor to center
of threaded rod to 13 1/2-inches).
- Adjust the horizontal seating of the bowl
support.
- Fully tighten the feet rod nuts.
ATTACHING THE FRAME TO THE WALL
- Mark the screw holes with a pencil.
- WARNING: If your wall is not perfectly
vertical, shim the frame with washers
(as per drawing ).
3 -
Use 6 3/8 x 3-inch lag screws to fasten
frame to the stud wall.
- Drill a 1/4-inch pilot hole.
- Use all 6 holes to fasten the frame
down to the wall.
- WARNING:
The distance between the supporting
wall and the front of the support frame
should not exceed 4-inches (100 mm).
The frame should fit flat against the wall.
WATER SUPPLY
1 -
Install a 1/2-inch water supply.
2 -
The water supply pipe must be fitted in
the upper part of the frame.
3 -
The pipe should terminate with a stop
valve (1/2-inch sweat x 3/8-inch
compression) with the handle of the
stop valve just visible below the top of
the frame.
7d
6
5
4
7c
2
1
7c
5
4
7a
2
1
7b
D
7a
3
7a
CB
A
2
E
7a
CDN/USA
4 -
The water supply pipe should be
fastened with clamps against the wall
in order to avoid any movements while
connecting the device.
5 -
For correct rinsing of the bowl, the
water pressure must be minimum
25 PSI (1,7 bar).
DISCHARGE CONNECTION
1 - The discharge pipe should be either
copper or CPVC or PVC solvent weld
pipe in 1" diameter.
2 - Put the end of the pipe through the
upper part of the frame.
WARNING : Use smooth pulled bends for
discharge pipework, or 2x45° bends in series.
Do not use 90° elbows.
CONNECTION OF WASHBASIN
1 - Connect washbasin waste via 1 1/4-inch
ABS or PVC pipe.
2 - Feed the waste pipe through either the
left or right hand side holes provided.
3 - IMPORTANT: The waste pipe should
terminate into the special connector
provided.
7g ELECTRICAL CONNECTION
WARNING: risk of electric shock- this pump is
supplied with a grounding conductor and
grounding type attachment plug to reduce the
risk of electrical shock. Be certain that it is
connected only to a properly gounded - type
receptacle.
• Plug the electrical cord into a receptacle
protected by a 15 Amp GFCI circuit breaker.
• Due to service requirements this electrical
supply should feed the SANISTAR
®
only.
7f
7e
7289 N°208 USA-CDN 26/11/07 9:18 Page 4