Dimensions Guide

PLEASE CALL US TOLL-FREE AT 800-571-8191 (US) / 800-363-5874 (CDN)
TO PURCHASE PARTS REFERENCED ABOVE
FOR ADDITIONAL TECHNICAL QUESTIONS, PLEASE CALL 800-571-8191
75.7 125.7 175.7 225.7 275.7 325.7 375.7
0
1
2
3
4
5
6
7
8
9
10
11
12
0
5
10
15
20
25
30
35
40
20 30 40 50 60 70 80 90 100
Flow Rate (liters/min)
Vertical Distance (m)
Vertical Distance (Feet)
Flow Rate (gallons/min)
P1 + P2
Discharge pipe diameter: 1
1
2"
Discharge rate at 36 ft: 38 GPM (Both motors in operation)
Discharge rate at 3 ft: 90 GPM (Both motors in operation)
Shut-off head: 45 ft.
Normal running time: Depends on number of fixtures
Capacity: 12.4 gallons
Inlets: 1
1
2" or 4" (sides), 1
1
2" or 4" (top)
Method of activation: Pressure switch, circuit board
Toilet, shower/bathtub base height: 10" min
Weight: 77 lbs.
Certifying agencies: CSA (IPC, NSPC), IAPMO (UPC)
Recommended accessories: Descaler
Connections: Toilets, sinks, shower/bathtubs,
washing machines (direct connection), etc.
19
1
1
1
4
1
6
1
1
1
2
2"
3"
3"
3"
23
3
3
3
4
27
1
1
1
8
8
DUPLEX GRINDING SYSTEM CAPABLE OF
DISCHARGING WASTEWATER FROM MULTIPLE
FIXTURES FROM ENTIRE BUILDING STRUCTURES
Two powerful 1 HP motors for absolute reliability and efficiency.
New grinding technology eliminates clogging issues found on
sewage ejector stations as it can handle feminine hygiene products.
Smart-pump technology allows both pumps to work
simultaneously if the incoming rate is higher than the discharge
rate of the single pump. The discharge rate increases roughly 80%
until the condition is alleviated.
System is capable of handling multiple fixtures at the same time
as it can handle up to 90 gallons per minute.
2
3
4"