Specification

E
XTENSION PIPE
The macerating pumps can
be installed stand alone or
b
ehind the wall with the use of
an extension pipe (maximum
length 18"). The bowl must
be raised by
3
8". Can only
be used with the Sanitop, Saniplus and Sanibest.
PIPE SUPPORTS
All sanitary pipe work must be supported in accordance
with the pipe manufacturers recommendations to avoid
dipping which may cause the build up of residual waste
and subsequent blockage.
BENDS
It is recommended to have the least amount of bends in
the discharge pipe work. These bends should not be 90˚
elbows as they restrict the flow. Use two 45˚ bends
back-to-back as this would create a smoother flow.
VERTICAL INSTALLATION
All vertical lifts should begin as closely as possible to
the discharge elbow. Therefore any horizontal run from
the discharge elbow should not exceed 12–18 inches.
(Except for Saniswift and Sanicubic as their discharge
is directly up and not across.)
EASY ACCESS
The macerating and gray water pump units should be
accessible and removable in the event that maintenance
is required. During installation, a “full-port” ball valve
may be fitted at the lowest portion of the vertical pipe.
This would facilitate the process if the discharge pipe
needs to be drained for any reason.
GRAVITY FALL
Gray water from other sanitary fixtures may drain into
the pump units by gravity. Therefore, all pipe work
connected into our unit must have a positive gravity fall
of at least 1/4 Inch per foot. Horizontal discharge pipe
work must also have a positive gravity fall to allow for
free drainage when the pump stops its cycle.
DIRECT FALL
When the point of discharge into the soil stack is
significantly lower than the macerating pump unit, as in
one or two stories, an anti-siphon valve may need to be
fitted at the highest point in the pipe run to avoid
siphoning of the water seal.
M
INIMUM SIZE DISCHARGE PIPE
All the pump units must have a minimum of three feet of
the required size of discharge pipe before transitioning
t
o a larger pipe size. This transition can only be
implemented in the last horizontal pitched discharge
line. This will allow the pump to operate for an
adequate period of time to ensure efficient waste
reduction.
SOIL STACK CONNECTION
The discharge pipe must be connected to the soil stack
by an appropriate and approved connection.
PIPE WORK MATERIAL
All discharge pipe work should be made out of ridged
copper or PVC/CPVC (schedule 40). Do not use flexible
or semi-flexible pipe.
FLUSHING
The Saniflush System requires a minimum of 1.6 gallons
(6 liters) of water to clean the pump satisfactorily. Our
self contained units require a minimum of 1 gallon
(4 liters) of water.
DISCHARGE
It is illegal to discharge into an open drain, ditch or
manhole. The waste needs to be pumped into a sewer
system, septic or holding tank.
FREEZING
Ensure all discharge pipe work susceptible to freezing is
adequately insulated. The toilet and pump units must be
properly winterized in un-heated buildings.
ELECTRICAL
All pumps are recommended to be connected to a
ground fault circuit interrupter. Before attempting any
servicing or maintenance the unit must be disconnected
from the power supply.
UPHILL PIPE RUNS
All “horizontal pipe runs should be self-draining. Uphill
or sloped pipe runs are not recommended as the solids
(no matter how small) will settle in the lowest portion of the
pipe run and may eventually block the pipe.
U.S. -105 Newfield Avenue, Suite B, Edison, NJ 08837
Toll Free: 1-800-571-8191
www.saniflo.com
Canada -
1 - 685 Speedvale Avenue West, Guelph, ON N1K 1E6
Toll Free: 1-800-363-5874
www.saniflo.ca
Copyright 2010 SFA SANIFLO, Inc. All rights reserved TS-0110
SANIFLO
®
MACERATING TOILET SYSTEMS
SANIPLUS
®
: used for toilet, sink,
bathtub, shower
Build a complete bathroom for
residential applications
Vertical pumping up to 15 ft. and 150 ft.
horizontally
Designed to work with our rear discharge toilet that only uses 1.6
gallons (6 liters) of water per flush
SANIPACK
®
: used for toilet, sink,
shower
Build a complete bathroom for residential
applications
Easy to conceal with versatile and quiet
operation
Vertical pumping up to 9 ft. and 100 ft. horizontally
Designed to work with North American wall-hung toilet systems
not supplied by Saniflo
SANICUBIC
®
Classic: used for whole
home/commercial applications with
several connected fixtures
Two powerful grinder pumps of 1 HP each
Vertical pumping up to 36 ft. and 328 ft.
horizontally
Suitable for several fixtures producing waste water up to
60 gallons per minute
Up to 5 inlets: or 4
Mounted control panel with Alarm, LED power control and
Over Load Indicator
SANISTAR
®
: used for toilet, sink
Build a half bathroom for residential
applications
Vertical pumping up to 9 ft. and 100 ft.
horizontally
Wall mounted. Compact macerating toilet
with built in macerator/pump. Uses just 1 gallon (4 liters) per flush
SANICOMPACT
®
: used for toilet, sink
Build a half bathroom for residential
applications
Vertical pumping up to 9 ft. and 100 ft.
horizontally
Compact macerating toilet for small areas.
Uses just 1 gallon (4 liters) of water per flush
EASILY AND QUICKLY INSTALL A TOILET, BATHROOM OR LAUNDRY ROOM ANYWHERE ITS NEEDED!
Self-Contained Units
SANIFLO
®
GRAY WATER PUMPS
TIPS FOR INSTALLING SANIFLO
®
PRODUCTS
SANITOP
®
: used for toilet, sink
Build a half bathroom for
residential applications
Vertical pumping up to 12 ft.
and 120 ft. horizontally
Designed to work with our rear discharge
toilet that only uses 1.6 gallons (6 liters) of water per flush
SANIBEST
®
: used for toilet, sink, bathtub, shower, washing
machine (indirect only)
Build a complete bathroom and more;
for residential and commercial
applications
Vertical pumping up to 18 ft. and 150 ft.
horizontally
Designed for heavy use, can occasionally accept disposal of
sanitary items
SANIGRIND
®
: based on our Sanibest
grinder pump
Build a complete bathroom and more; for
residential and commercial applications
Vertical pumping up to 18 ft. and 150 ft.
horizontally
Great for retrofitting applications. Designed to work with
standard bottom outlet toilets not supplied by Saniflo
Designed for heavy use, can occasionally accept disposal of
sanitary items
SANIVITE
®
:
used for a
complete kitchen,
wet bar etc...
Discharges
18 gallons
per minute
Vertical pumping up to 16 ft. and 150 ft.
horizontally
Small enough to fit inside a kitchen
cabinet with the capability to handle hot
water. Ideal for heavy-duty applications
SANISWIFT
®
:
used for laundry
room, sink, shower,
dishwasher
Discharges 18
gallons per minute
Vertical pumping up to 14 ft. and 140 ft.
horizontally
Multiple inlets for various installations
SANISHOWER
®
:
used for shower,
sink, wet bar
Discharges
14 gallons
per minute
Vertical pumping up to 12 ft. and 100 ft.
horizontally
Easy to install and small enough to
fit under the shower base
Ideal for light-duty applications
External Units
Quiet Design
Quiet Design

Summary of content (2 pages)