Specification Sheet

CONNECTIONS
SANIACCESS 3 • PART N
O
082
Macerator
The Saniaccess3 is a 1/2 HP pump system used to install a complete bathroom up to 15 feet below the sewer
line, or even up to 150 feet away from a soil stack. It incorporates a macerating system which can handle
human waste and toilet paper in residential applications. The blade is made out of a hardened stainless steel
material which eliminates the need for any service or replacement.
Discharges the waste through a 34” or 1” rigid pipe. A non-return valve is included on the discharge
elbow assembly provided with the system. This elbow can be rotated 360 degrees depending on the
discharge installation.
Has been designed with a 1–12” vent connection on the top of the lid. All plumbing codes require
connection to a vent system. Please note that the vent system should be a two-way air vent as air needs
to freely flow both ways. Note: The use of mechanical vents, air admittance valves or similar devices
is not permitted.
Must be connected to Saniflo’s 1.28 GPF / 4.8 LPF rear discharge toilet. These toilets come in round
and elongated (ADA compliant) models. More technical information on page 6.
Will also discharge gray water from any sink, bath/shower or urinal. The wastewater will drain into
the system via two 2” inlets with built-in check valves on either side of the housing. Note that when
adding a bathtub/shower, the base should be raised up by a minimum of 6” off the floor.
Designed with two easy access service panels located on top of the pump. On one side
of the pump you can easily access the electrical components and the level sensor.
The other side allows access to the macerating blade for easy removal of foreign objects.
INSTALLATION BEHIND THE TOILET
INSTALLATION BEHIND THE WALL
ASME A112.3.4
3
Example of installation. Follow local plumbing codes for actual install. Example of installation. Follow local plumbing codes for actual install.
PUMPING DISTANCE
APPLICATION
RESIDENTIAL
TOILET
SHOWER
SINK
BATHTUB
15 Ft
150 Ft
Toilet Tank
(Part N
o
005)
Insulated 1.28 GPF / 4.8 LPF toilet tank equipped with all
internal valves. For more information, please turn to page 6.
Round/Elongated Bowl
(Part N
o
083 or 087)
Rear discharge toilet with 16–34” seating height (Elongated bowl
is ADA compliant). For more information, please turn to page 6.
Extension Pipe
(Part N
o
030)
18” long PVC pipe with internal gasket used to hide the pump
behind the wall. For more information, please turn to page 51.
SaniAccess 3
(Part N
o
082)
1/2 HP macerating pump for residential applications. Dual
service access panels for possible maintenance and service.
10