TROUBLESHOOTING
CAUSE:
1) Low battery
2) Main 30A fuse blown
SOLUTION:
1) Check/Charge battery.
2) Replace GREEN 30A fuse.
THE MACHINE DOES NOT START UP
NO SOLUTION COMES OUT
THE MACHINE LEAVES SOLUTION ON THE FLOOR
THE BRUSH DOES NOT ROTATE
THE MACHINE DOES NOT CLEAN WELL
CAUSE:
1) Brush unit outlet overcurrent error or brush
unit open circuit error
2) Brush rotation button not pressed on handle
controls
CAUSE:
1) Vacuum off
2) Vacuum tube blocked
3) Squeegee rubbers not correctly set up
4) Recovery tank full
5) Squeegee rubber blades worn
CAUSE:
1) Solution tank empty
2) Solenoid valve button not pressed on handle
controls
3) Tap turned off
4) Filter blocked
5) Solenoid valve does not work
CAUSE:
1) Unsuitable brushes or cleaning solution
2) Brush worn
SOLUTION:
1) See paragraph ‘Warning signals while using
the machine (Section 5)
2) Press the button
SOLUTION:
1) Start the vacuum
2) Check, and if necessary, clean the vacuum
tube that connects the squeegee to the
recovery tank
3) Correct squeegee position
4) Empty the recovery tank
5) Replace or tun over the squeegee blades
SOLUTION:
1) Fill the tank
2) Press the button
3) Turn on the tap located at the bottom of the
machine
4)Cleanthelter
5) Replace solenoid valve
SOLUTION:
1) Use brushes or cleaning solutions which are
suitableforthetypeofoorordirttobecleaned
2) Replace the brush
THE VACUUM DOES NOT WORK
CAUSE:
1) Suction unit outlet over current error or
vacuum unit circuit error
2) Vacuum button not pressed on handle
controls
SOLUTION:
1) See paragraph ‘Warning signals while using
the machine (Section 5)
2) Press the button
* If the fuse blows several times, the machine should be checked by an authorised Service Agent