SDS
SAPC-001 - S-T Drain Opener
Revision Date: 03-Jul-2015
_____________________________________________________________________________________________
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing Media
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Unsuitable Extinguishing Media
Not determined.
Specific Hazards Arising from the Chemical
Not determined.
Hazardous Combustion Products Contact with soft metals may evolve flammable hydrogen gas.
Protective equipment and precautions for firefighters
As in any fire, wear self
-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full
protective gear.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal Precautions
Use personal protective equipment as required.
Environmental Precautions
See Section 12 for additional Ecological Information.
Methods and material for containment and cleaning up
Methods for Containment
Prevent further leakage or spillage if safe to do so.
Methods for Clean-Up
Soak up with absorbent material. Neutralize with an alkaline material. Collect spillage.
Dispose of contents/container to an approved waste disposal plant.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on Safe Handling
Handle in accordance with good industrial hygiene and safety practice. Wear protective
gloves/protective c
lothing and eye/face protection. Do not breathe
dust/fume/gas/mist/vapors/spray. Wash face, hands, and any exposed skin thoroughly after
handling. Keep only in original container.
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep container tightly closed and store in a cool, dry and well-ventilated place. Store locked
up. Store in corrosive resistant container with a resistant inner liner.
Incompatible Materials
Metals. Water. Chlorine bleach. Oxidizing agents.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Exposure Guidelines
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Sulfuric Acid
7664-93-9
TWA: 0.2 mg/m
3
thoracic fraction
TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 15 mg/m
3
TWA: 1 mg/m
3
Appropriate engineering controls
_____________________________________________________________________________________________
Page 3 / 8