Use and Care Guide
Table Of Contents
- TOC-Important-Installation-Guidelines
- TOC-Model-Differences
- TOC-Check-Contents-of-Box
- TOC-Do-Not-Remove-Paper-Mat
- TOC-Important-Notices
- TOC-Ready-to-Go-
- TOC-90-Bends-in-Vent
- TOC-1.-Position-Toilet
- TOC-1
- TOC-2.-Cut-Vent-Hole-in-Roof-Ceiling
- TOC-2
- TOC-3.-Vent-Roof-Stack-Installation
- TOC-3
- TOC-4.-Insert-Vent-Pipe-into-System
- TOC-4
- TOC-5.-Attach-Union-Coupling-Optional-
- TOC-5
- TOC-6.-Connect-Remaining-Vent-Pipe
- TOC-7.-Install-Drain
- TOC-8.-Seal-All-Vent-Connections
- TOC-9.-Insulate-Exposed-Pipe
- TOC-6
- TOC-10.-Attach-Rain-Cap-or-Wind-Turbine
- TOC-Protect-from-the-Elements
- TOC-Install-Rigid-Vent-Pipe-not-supplie
- TOC-Connect-Flexible-Vent-and-Rigid-Pip
- TOC-Attach-Wind-Turbine-Ventilator-
- TOC-Seal-All-Vent-Connections
- TOC-Install-Vacuum-Toilet
- TOC-Install-Drain
- TOC-Connect-Three-Components-of-System
- TOC-Start-Here
- TOC-Position-the-System
- TOC-Connect-Vacuum-Toilet-to-Vacuum-Gen
- TOC-Connect-Vacuum-Generator-to-Compost
- TOC-Fasten-Vacuum-Generator-Unit-and-Co
- TOC-Connect-Vacuum-Generator-to-12v-Pow
- TOC-Connect-Composting-System-to-AC-Ele
- TOC-Plug-Play-Wiring-Connection
- TOC_Do_Not_Add__3175881415145758
- TOC_Rated_Capacity_4164048674046512
- TOC_Operation_is_Easy_8826685531918387
- 1_System_Operation_09638061436967571
- TOC_1_Initial_System_Start_Up_1095042459
- TOC-1.-Initial-System-Start-Up
- TOC_2_Power_Control_42472747931111743
- TOC-2.-Power-Control
- Non_Electric_SystemsNot_applic_933833838
- FlushSmart_VF_models_Always_tu_554945394
- TOC_12VDC_Systems_12964841970897056
- TOC-12VDC-Systems
- FlushSmart_VF_models_Always_tu
- 5_Weekly_Operation_5923775715714038
- TOC-Typical-Emptying-Times
- TOC-Indications-of-Emptying-Required
- TOC-Before-you-Empty
- TOC_Introduction_3353822634090_525738961
- Proper_System_Operation_1312612757753413
- TOC_Outside_Odour_901114465392_444162368
Use as directed. To ensure proper performance, please be sure to contact us if you have installation or operation questions.
ENVIROLET®/SG INSTALLATION & OPERATION MANUAL (7MINS11D 12.15) • Envirolet® is a registered trademark. ©2016, Sancor Industries Ltd.
19
Envirolet®/SG FlushSmart VF: Components & Tools Required
Envirolet®/SG FlushSmart VF System included components (standard system).
Components
The following is a list of items included with your Envirolet®/SG FlushSmart VF System.
#
Quantity
Unit
Item
1
1
Each
Vacuum Toilet (300, 700 or 800 Series model) with instructions, mounting kit &
accessories
2
1
Each
Envirolet®/SG Composting Unit (North America: 120VAC Electric, CSA Electric
or Europe/Scandinavia: 230VAC Electric, 50Hz, 2.2A, IPX4, CE, Semko)
3
1
Each
Vacuum Generator Unit with instructions
4
1
Each
Vacuum Generator Fuse Breaker
5
1
Each
AC Power Supply Unit (120VAC/12V, 10A or >)
6
1
Each
4”/110m Wind Turbine Ventilator
7
1
Each
Electronic Switch for Vacuum Toilet (700 Models only)
8
4’/1.2m
Length
4”/110mm Vent Hose with 4.0”/110mm Coupling
9
16.0’/4.9m
Length
1.5”/38mm VG4/Toilet/Envirolet®/SG Compost Unit Connecting Hose
10
4
Each
1.5”/38mm Drain Hose Gear Clamps
11
1
Each
4”/110mm Vent Gear Clamp
12
5.0’/152cm
Length
0.5”/13mm Drain Line
13
1
Each
Silicone Hose & Fitting Lubricant (small tube)
14
1
Each
Water Supply with Pre-Set Water Volume Control Regulator
15
1
Each
Silicone Sealant Tube (small)
16
2
Each
Premix Starter Mix Kit (bag)
17
1
Each
8oz/236mL Compost Accelerator
18
1
Each
Daily Mix (sample size); Not included in Norway
19
1
Each
Drain Breather “T”
Not Included but Required
For most FlushSmart VF installations solvent cement CPVC is required.
** CONNECTING HOSE MAY BE SUPPLIED IN ONE LENGTH SO END-USER CAN CUT AND FIT TO SPECIFIC INSTALLATION
REQUIREMENTS.