Use and Care Guide

Table Of Contents
Use as directed. To ensure proper performance, please be sure to contact us if you have installation or operation questions.
ENVIROLET®/SG INSTALLATION & OPERATION MANUAL (7MINS11D 12.15) • Envirolet® is a registered trademark. ©2016, Sancor Industries Ltd.
44
B. The “B” model requires straight plastic fitting to be connected to the below floor cup - use solvent-cement (CPVC) to seal
straight plastic fitting (on this “B” model only).
C. Position and install floor mounting kit to floor position and install toilet to floor mounting kit
D. Make sure rubber O”-ring around base of VF300 “B” model toilet only is well lubricated with silicone grease and insert toilet
base carefully in below floor mounting cup to prevent pinching or damage to “O”-ring.
E. Failure to solvent cement plastic fittings will cause loss of vacuum and vacuum pump to continuously run.
Important
In below floor models (B”), ensure that the rubber seal between vacuum toilet and floor flange is liberally lubricated to ensure proper
vacuum seal.
Important
Please refer only to Envirolet®/SG instructions for the following:
Wiring (see Plug & Play section)
Draining (see Draining section)
Operation (See Start-Up & Operation section)
Tankconnections (this section)
Fasten Vacuum Generator Unit and Composting Unit to Floor
A. Fasten Vacuum Generator Unit to floor to prevent movement with floor mounting brackets found on unit.
Important
Please refer only to Envirolet®/SG instructions for the following:
Wiring (see Plug & Play section)
Draining (see Draining section)
Operation (See Start-Up & Operation section)
Tankconnections (this section)
B. Fasten Envirolet®/SG Composting Unit to floor to prevent movement with floor mounting brackets found on unit.
Connect Vacuum Generator to AC Power Supply (AC Models only)
A. Connect Vacuum Generator Unit to Power Supply Unit (not included with 12VDC models). Refer to Plug & Play
instructions for wiring diagrams.
B. Install Power Supply 1-3‘ (0.3-0.9m) off floor to keep dry and away from dust and near to vacuum generator and
composting unit.
C. Black wire is always negative (-).
D. All wires are connected to plastic pin snap-lock fasteners for easy connection
VF700 Series (4 wire connections)
Connect red and black wire connection from 12v power supply to vacuum generator.
Connect red and black wire connection from 12v power supply to toilet.
Connect black and green wire from vacuum generator to toilet.
Connect wire from wall-mounted switch to toilet.
Plug in AC power plug only on power supply to certified and grounded AC wall outlet only
VF300 Series (1 wire connection)
Connect red and black wire from 12v power supply to vacuum generator.
Plug in AC power plug only on power supply to certified and grounded AC wall outlet only.
Connect Composting System to Power
A. Connect AC Electric model Envirolet®/SG Composting Units to grounded, approved and certified 120VAC or 230VAC
Electric power receptacle. Be sure to follow all safety instructions. Refer to Plug & Play instructions for wiring diagram.
B. Connect DC model Envirolet®/SG Composting Units to 12V power source. Be sure to follow all safety instructions. Refer to
Plug & Play instructions for wiring diagram.