Use and Care Guide

Table Of Contents
Use as directed. To ensure proper performance, please be sure to contact us if you have installation or operation questions.
ENVIROLET®/SG INSTALLATION & OPERATION MANUAL (7MINS11D 12.15) • Envirolet® is a registered trademark. ©2016, Sancor Industries Ltd.
57
2. Start of Season: System Start-Up
Complete all installation, including venting, draining, etc., before beginning Initial System Start-Up.
SYSTEMS THAT REQUIRE EMPTYING START HERE
Empty System
Ignore this step and begin at step 4 if the system is new and has not yet been used.
Typically, you will empty your system at the start of the season. For full-time use or heavier use emptying periods will vary.
Refer to Emptying Instructions section for instructions.
Clean drain line and filters
After emptying and before replacing bottom panel, be sure to inspect your drain line and filters (tray and drain) in systems
with excess liquid drains installed.
Ensure that drain and filter cloths are free of debris. Replace if required.
CHECK ALL AIR AND LIQUID SEALS
After emptying and replacing bottom panel, be sure to inspect that all openings in system are completely sealed for liquid
and air.
Make sure bottom panel is properly attached and that all areas that silicone-sealed have a proper seal.
NEW SYSTEMS START HERE
Add Premix Starter Mix to Envirolet®/SG Composting System
For Waterless Self-Contained models:
Open toilet seat, open trap and remove bowl to add.
Spread contents as evenly as possible over Paper Mat in system. If Paper Mat was accidentally removed, please spread
single-ply toilet paper over Manifold Grid. Be careful to avoid Mulcherator cutting blades.
For Waterless Remote, Low Water Remote and FlushSmart VF models:
Remove Service Panel on composting unit/tank to add.
Spread contents as evenly as possible over Paper Mat in system. If Paper Mat was accidentally removed, please spread
single-ply toilet paper over Manifold Grid. Be careful to avoid Mulcherator cutting blades.
Low Water Remote and FlushSmart VF models will have 2 bags of Starter Mix to add. Use both.
Add a small glass (8oz/235ml) of warm water over Starter Mix inside system.
Replace bowl and close toilet seat (Waterless Self-Contained models) or replace Service Panel on composting unit
(Waterless Remote, Low Water Remote and FlushSmart VF models).
Power up system! If system is not plugged in, plug it in now. Fans will start to turn.
DC and AC Electric models:
Turn Control Switch to Normal Mode in Position 2.
System should be left in Position 2 for best performance. More about operation modes in Power Control and Daily Operation
sections.
In FlushSmart VF models, turn on the vacuum generator unit.
Non-Electric models:
Not applicable.
Your Envirolet®/SG Composting Toilet System is now ready to use!
Please follow all operation guidelines for proper system performance and familiarize yourself with basic operation steps (below) before
use.
3. Composting Unit Power Control
Envirolet®/SG AC Electric and 12VDC Systems are equipped with a 2-Position toggle power Control Switch that controls the electric
components in the Envirolet Works-in-a-Drawer™ Box. Non-Electric models The switch is located on the Top Panel of the Compost
Unit. Please familiarize yourself with the information about your system below.
Non-Electric Systems
Not applicable. Non-Electric models do not use any power (unless an optional 12VDC or AC Electric in-line Turbo Fan has been
installed).