Envirolet®/Santerra Green Composting Toilet Systems Installation & Operation Manual Please read this manual carefully before installation and follow all guidelines for proper system performance. Sancor Contact information USA 1-800-387-5126 CANADA 1-800-387-5245 DIRECT +1 416 299 4818 EMAIL support@sancorindustries.com WEB sancor.ca Envirolet® USA & WORLD envirolet.com CANADA envirolet.ca EUROPE envirolet.eu NORWAY enviroletnorge.com FINLAND enviroletfinland.com Manufactured by Sancor Industries Ltd.
TABLE OF CONTENTS – Key areas are marked with a ★ Envirolet® and Santerra Green™ ..................................................................................................... 2 Congratulations ................................................................................................................................. 2 ★START HERE: Read Before Installation ....................................................................................... 3 Safety Guidelines ..............................
START HERE: Read Before Installation This is where to start the installation process! Read this section before installation of your Envirolet®/SG Composting Toilet System. Look for These Symbols Pay close attention to the and symbols used throughout this manual for important notes and warnings. IMPORTANT! READ THIS ENTIRE SECTION BEFORE INSTALLATION Learn About System • • • • It is essential to use proper care in the installation, operation and maintenance of your system.
IMPORTANT INSTALLATION GUIDELINES Please read and understand all of these basic installation guidelines before beginning the installation of your Envirolet®/SG Composting Toilet System. We have included a check box area to help you. # GUIDELINE CHECK 1 Inspect package (box) contents immediately upon delivery of system to ensure that there are no missing or broken parts. Report any issues within 24 hours.
SPECIAL NOTE FOR SYSTEM INSTALLERS, INCLUDING CONTRACTED INSTALLERS (PLUMBERS, CONTRACTORS, HANDYMEN/WOMEN, ETC.) This is a composting toilet system and does not install in the same manner a standard flush toilet does. We use special venting and draining designed to work with our systems. Please pay careful attention to our instructions and contact us for assistance if required. An incorrectly installed system may have service/performance issues.
Safety Guidelines Important Envirolet®/SG safety guidelines and information. READ FIRST Please read this section carefully and follow all guidelines. Educate all system users on these safety guidelines. • • • • • • • Safety Warning Fire Hazard Warning AC Power Cord 120VAC Electric Models 230VAC Electric Models Electric Components More Important Safety Guidelines SAFETY WARNING For your safety, please follow all safety guidelines before beginning the installation process.
AC POWER CORD The AC power cord on your Envirolet®/SG System is approximately 3m/9ft long. Plug the power cord to a certified and grounded (3prong in North America) plug wall outlet or receptacle. Modification to electrical components may be unsafe and will void warranty. 120VAC ELECTRIC MODELS The receptacle should be connected to a 120VAC, 60hz, 15-amp fuse service in your main electrical box. No extension cords should be used. Do not cut, extend or hard wire.
Certified For Use On top of being used in-the-field for over 30 years, Envirolet®/SG Composting Toilet Systems are certified for use. Certified in North America Certified in Europe In North America, Envirolet®/SG Composting Toilet Systems have been certified by CSA (Canadian Standards Association) to meet various certifications including CSA ANSI/NSF Standard-41. Your Envirolet®/SG Composting Toilet System is CE certified to meet European standards.
Envirolet®/SG: Helping You To Go Green! Congratulations on your decision to go green! Even if you chose to use an Envirolet®/SG for other reason (ease of installation, economical, etc.) you have still gone with a green sanitation solution! Attractive & Modern Envirolet®/SG offers clean and modern bowl-design options that look great in any bathroom.
How the process works in all 4 System types. Visit our website for more detail information. Envirolet®/SG Waterless Self-Contained System Envirolet®/SG Waterless Remote System Air is drawn in through toilet seat in bathroom. Air is drawn in through toilet seat. Small gap between toilet bowl and trap allows this. Envirolet®/SG Low Water Remote System Air is drawn in through service panel. Envirolet®/SG FlushSmart VF System Air is drawn in through service panel. Use as directed.
Systems/Models Models that these instructions refer to. Please be sure to follow the instructions for your specific model.
Envirolet®/SG Waterless Remote Models WATERLESS, TOILET ABOVE, TANK BELOW NORTH AMERICA Non-Electric: Envirolet® Waterless Remote NE/Santerra Green™ Y40 (4UEWRNE06, 4CEWRNE06) 12VDC: Envirolet® Waterless Remote DC/Santerra Green™ Y50 (6UEWSDC06, 6CEWSDC06) 120VAC: Envirolet® Waterless Remote AC/Santerra Green™ Y60 (5UEWRAC06, 5CEWRAC06) EUROPE AND SCANDINAVIA Non-Electric: Envirolet® Waterless Remote NE/Santerra Green™ Y40 (4CEWRNE06-CE) 12VDC: Envirolet® Waterless Remote DC/Santerra Green™ Y50 (6CEWS
Envirolet®/SG Low Water Remote Models 0.
Envirolet®/SG FlushSmart VF Models 0.
FlushSmart Model Differences • 300, 700 and 800 Series Models • 320, 720 and 820 Series Models 1 toilet and 1 composting unit/tank. 120VAC or 230VAC. 1 toilet and 1 composting unit/tank. 12VDC. • 350, 750 and 850 Double Tank Series Models • 1 toilet and 2 composting units/tanks. 120VAC or 230VAC. • 370, 770 and 870 Double Tank Series Models 1 toilet and 2 composting units/tanks. 12VDC.
BEFORE INSTALLATION: Inspect Box & Contents Inspect box and contents upon delivery to make sure you received everything. Please read this before continuing with installation to ensure there are no missing or broken parts. IMPORTANT Check contents of system and accessory box(es) before beginning installation and report any missing parts or damage immediately. There are a few important things to do before you begin the installation process of your new Envirolet®/SG Composting Toilet System.
Included System Components - What’s in the Box List of included items for each system type. Look for the packing slip included with the system. Tools Required for Most Installations Suggested tools to have on hand for easy installation. • • • • Hand drill Jig-saw Screwdrivers (Philips, flathead) and/or drill Plumb line (to line up vent) Got Everything? Be sure to check the contents of the box to make sure you have everything.
Envirolet®/SG Waterless Remote: Components & Tools Required Envirolet®/SG Waterless Remote System included components (standard system). Components The following is a list of items included with your Envirolet®/SG Waterless Remote System. # 1 2 Quantity 1 1 Unit Each Each 3 4 5 6 7 8 9 10 11 12 13 1 2’/60cm 1 4’/1.2m 1 5.
Envirolet®/SG FlushSmart VF: Components & Tools Required Envirolet®/SG FlushSmart VF System included components (standard system). Components The following is a list of items included with your Envirolet®/SG FlushSmart VF System. # 1 Quantity 1 Unit Each 2 1 Each 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1 1 1 1 1 4’/1.2m 16.0’/4.9m 4 1 5.
System Installation Please follow the installation guidelines for your specific system type. Envirolet®/SG Waterless Self-Contained System Installation PLEASE READ THIS SECTION CAREFULLY. Envirolet®/SG Composting Unit refers to the complete Envirolet®/SG Waterless Self-Contained System. Important Notices IMPORTANT Do not connect Envirolet®/SG Composting Unit (System) to power supply until instructed (after all components have been individually installed).
H. I. J. Seal All Vent Connections Insulate Exposed Pipe Attach Rain Cap or Wind Turbine Ventilator 1. Position Toilet IMPORTANT It is recommended that your Envirolet®/SG vent system is installed completely “vertical” (or straight-up) for best operation. However, if an angled vent system is required be sure to use only two 45° elbows maximum without consulting us for advise. An optional inline Turbo Fan may be required for extended, angled, or difficult vent designs or installations.
5. Attach Union Coupling (Optional) The optional Union Coupling will allow for quick disconnection of your vent system for convenient servicing, if required, of either your Envirolet®/SG system or the “Works-in-a-Drawer” electrical service compartment. A. B. Use the Union Coupling provided (optionally) to join securely the 3”/75mm Vent Connection on the Envirolet®/SG system to the “first” section of 3”/75mm White Pipe installed on your vent installation.
Envirolet®/SG Waterless Remote System Installation PLEASE READ THIS SECTION CAREFULLY. Important Notices IMPORTANT Do not remove the Paper Mat located in Envirolet®/SG Composting Unit. This is not packing material. It is an important component to proper system start-up. WARNING The vent system must always be securely attached to your Envirolet®/SG Composting Unit before any operation. Failure to comply could result in an unsafe electrical hazard.
Waterless Toilet Installation 1. Position Waterless Toilet A. B. Determine where you will be installing the Waterless Toilet. Do not do any cutting of the floor until you are sure! Remember that the Waterless Toilet must be directly above the Composting Unit for a gravity drop. Refer to Waterless Toilet Floor Hole Guide below for placement specifications.
2. Cut hole in floor for Waterless Toilet A. Follow lines and carefully cut hole in floor using jigsaw or similar tool depending on tools available and floor type. IMPORTANT When cutting your floor hole, It is always best to initially make a hole that is too small because you can always make it larger. But, you cannot make it smaller! B. Drill holes in floor (E and F) for mounting bolts. 3.
C. Attach rubber gasket seal to bottom of Waterless Toilet. Place adhesive side of gasket inside recessed area of bottom of toilet. D. Insert Waterless Toilet into hole in floor. The chute (bottom part of the Waterless Toilet) should fit through hole in floor. E. Centre/align Waterless Toilet in desired position. F. Using included mounting hardware (bolts, nuts, washers) secure Waterless Toilet to floor. G. Insert large bolt through open slot on Waterless Toilet and through bathroom floor. H.
3. Install Rigid Vent Pipe (not supplied) Rigid Vent Not included, due to transportation costs, is 10’/3m to 20’/6m (for a typical installation) of rigid ABS or PVC Pipe that is required to complete vent installation. This rigid pipe travels up along the wall of your structure above the roof line (minimum 2’/0.6m) and is fitted with the included Wind Turbine Ventilator. The rigid pipe connects to the 4”/110mm Flex Vent Pipe via an attached 4”/110mm coupling provided.
B. C. D. Connect other side of “T” to length of 13mm/1/2” drain line. Place end of drain line to an acceptable drain site (leach field, holding tank, liquid container, etc.). See Draining Information section for more details. Make sure there is a gravity drop the entire path from composting tank drain exit to drain site. Insulate drain line if there is a chance of freezing. IMPORTANT Please be sure to connect excess fluid drain to an acceptable drain site, according to local regulations.
Envirolet®/SG Low Water Remote System Installation PLEASE READ THIS SECTION CAREFULLY. Important Notices IMPORTANT Do not remove the Paper Mat located in Envirolet®/SG Composting Unit. This is not packing material. It is an important component to proper system start-up. WARNING The vent system must always be securely attached to your Envirolet®/SG Composting Unit before any operation. Failure to comply could result in an unsafe electrical hazard.
Low Water Toilet Installation IMPORTANT Do Not Use Any Harsh Chemicals In Toilet. This can damage the seals and valves in the toilet and damage the biological action in your composting toilet unit. IMPORTANT Do Not Place or Flush Large Objects such as paper towels, diapers, sanitary napkins etc. down toilet. IMPORTANT Toilet must be regularly cleaned and winterized to protect porcelain bowl and seals. IMPORTANT Use only non-toxic “green cleaners” to clean the toilet bowl.
mounting pattern. Insert mounting bolts into slotted holes in flange. Push fit flange through hole to floor and secure flange to floor using flat head screws through the countersunk holes in flange (see FIGURE B). FIGURE B If desired spread bead of silicone sealant around outer edge of floor-flange (seeFIGURE C). FIGURE C Place and align rubber toilet seal over mounting bolts on floor flange.
FIGURE E Turn on water supply. Flush toilet to check for any leaks. Attach pedestal and pedal cover using screwdriver. See multiple drawings (see FIGURE F). FIGURE F 3. Winterizing Low Water Toilet Turn off water supply. Disconnect 0.5”/12.7mm water supply connection on low water toilet. Flush and dry thoroughly toilet bowl and rubber seal in toilet of any water (see FIGURE B). For complete details be sure to read Winter Use section. Use as directed.
WARNING Do not use anti-freeze or any chemicals in toilet as this can damage Composting Unit and/or the natural composting process. Composting Unit Installation 1. Position Envirolet®/SG Composting Unit Locate in Covered Structure Position the Envirolet®/SG Composting Unit in a covered structure (work shop, basement, garden shed, utility shed, box, etc.) in area that is free of obstructions (pipes, electric boxes, wires, etc.).
3. Install Rigid Vent Pipe (not supplied) Rigid Vent Not included, due to transportation costs, is 10’/3m to 20’/6m (for a typical installation) of rigid ABS or PVC Pipe that is required to complete vent installation. This rigid pipe travels up along the wall of your structure above the roof line (minimum 2’/0.6m) and is fitted with the included Wind Turbine Ventilator. The rigid pipe connects to the 4”/110mm Flex Vent Pipe via an attached 4”/110mm coupling provided.
B. C. D. Connect other side of “T” to length of 13mm/1/2” drain line. Place end of drain line to an acceptable drain site (leach field, holding tank, liquid container, etc.). See Draining Information section for more details. Make sure there is a gravity drop the entire path from composting tank drain exit to drain site. Insulate drain line if there is a chance of freezing. IMPORTANT Please be sure to connect excess fluid drain to an acceptable drain site, according to local regulations.
Envirolet®/SG FlushSmart VF Installation READ BEFORE INSTALLATION. IMPORTANT It is advised to completely read your owner’s manual instructions carefully before beginning installation. Doing so will safe you time and allow for an easier installation overall. Start Here It is important that your Envirolet®/SG FlushSmart VF Composting Toilet System be installed correctly for proper operation and performance.
SINGLE TANK SYSTEM DOUBLE TANK SYSTEM Below are some things to consider before beginning the installation process. Position the System Position the vacuum toilet, vacuum generator and Envirolet®/SG composting unit in an area that is free of obstructions (pipes, electric boxes, wires, etc.). Try to keep composting unit in area with an ambient temperature above 12°C (55°F) for optimum composting. Refer to the Winter Use section if you plan to use the system in freezing or near-freezing temperatures.
IMPORTANT At this stage, you can place components roughly where they will be installed (positioning), but do not attach to floor or connect to other system components until directed. IMPORTANT Do not connect vacuum toilet or vacuum generator to Envirolet®/SG Composting Unit/Tank until instructed (after all components have been individually installed). Envirolet®/SG FlushSmart VF: Composting Unit Installation Installation instructions for the Envirolet®/SG FlushSmart VF composting unit.
90° Bends in Vent IMPORTANT It is recommended that the 100mm/4” vent pipe be installed straight up, with little or no angles/bends in the venting system. This will ensure proper vent draft and evaporation, and prevent any inside odour. Do not install any 90° bends (or greater) in your vent installation. Ready to Go! It’s time to begin installation of the composting unit component of your Envirolet®/SG FlushSmart VF System! Here are the main steps: 1. Position Envirolet®/SG Composting Unit 2.
• • • Place 4”/110mm Flex Vent pipe section over vent opening on the Top Panel of Envirolet®/SG Composting Unit (tank) using the supplied 4”/110mm stainless steel Gear Clamp. Tighten Gear Clamp over Flex Vent to secure to plastic opening for proper seal. Based on your individual installation requirements, you may wish to increase or decrease the length of the 100mm/4” Flex Vent pipe (4’/1.2m is standard).
Important Make sure open part of “T” (middle) is facing up to prevent air-lock. • • • Connect other side of “T” to length of 13mm/1/2” drain line. Place end of drain line to an acceptable drain site (leach field, holding tank, liquid container, etc.). See Draining Information section for more details. Make sure there is a gravity drop the entire path from composting tank drain exit to drain site. Insulate drain line if there is a chance of freezing.
“A - Above Floor Rear” - Connects to fitting at back of vacuum toilet in VF300 models and to cup fitting in VF700 models. o “B - Below Floor” - Connects to included floor flange fitting below the bathroom floor. o Apply included lubricant to inside of 1.5” flex drain hose and outside fittings to allow for easier connection. o Use 2 x Gear Clamps for tight fit. It is essential that 2 be used.
Ø “B” - Below Floor (with right-angle fitting) • • • Envirolet FlushSmart VF700 Series models include VF700 toilet and floor mounting cup kit. Position and install floor-mounting kit to floor position and install toilet to floor mounting kit. Make sure rubber “O”-ring around base of VF700 toilet is well lubricated with silicone grease and insert toilet base carefully in floor mounting cup to prevent pinching or damage “O”-ring.
B. C. D. E. The “B” model requires straight plastic fitting to be connected to the below floor cup - use solvent-cement (CPVC) to seal straight plastic fitting (on this “B” model only). Position and install floor mounting kit to floor position and install toilet to floor mounting kit Make sure rubber “O”-ring around base of VF300 “B” model toilet only is well lubricated with silicone grease and insert toilet base carefully in below floor mounting cup to prevent pinching or damage to “O”-ring.
Envirolet®/SG FlushSmart VF: Plug & Play Envirolet®/SG FlushSmart VF Systems are Plug & Play ready-to-install. Document link for printing • Short URL: http://bit.ly/fsvfpp Plug & Play Wiring Connection • • • Envirolet®/SG FlushSmart VF come Plug & Play ready-to-go! All the wiring is comprised of colour-coded snap-together connectors to make it simple. Please refer to these diagrams for connection instructions (links open PDF file).
Directions • • Connect 5/8” (15.87 mm) end of water supply to vacuum toilet, then connect 3/8” (9.525mm) end of water supply to a proper fitting on water pipe. The Water Control Regulator is preset in the 5 and/or 11 o’clock or position indicator 573.
Draining & Typical Drain Pit Design Draining information and typical drain pit design. PLEASE CHECK LOCAL REGULATIONS REGARDING DRAINING. Some systems are fitted with an excess liquid drain kit. This drain must gravity connect to a leaching pit or acceptable drain site for proper system performance. Systems with drain kit included standard: • • • All Non-Electric models. All 12VDC models. All water flush (Low Water Remote and FlushSmart VF) models.
• Or, connect to a 10+ gallon plastic container (will require periodic emptying to proper disposal site). A drain pit is ideal where possible. A. B. In order to allow for proper flow the drain line must be gravity connected its entire path from toilet system to drain site. Ensure that Quick Connect “T” is used with the breather tube pointing upwards to prevent “air lock” or drain blockage. See image above in Waterless section.
Envirolet®/SG System Winter Use Envirolet®/SG Systems can be used in winter applications as long as certain precautions are taken to ensure for proper performance. Each system type has some specific requirements. Read the information for your system type. Need Help? It is important that your system is properly winterized for proper performance. Please be sure to contact Sancor for additional information or support for the winter operation of your Envirolet®/SG System.
Envirolet®/SG Waterless Remote Winter Use IMPORTANT Your Envirolet®/SG Waterless Remote System can be used during winter, cold or freezing conditions. It does not use water to flush and therefore less precaution (compared to water flush models) must be taken before using in winter due to concerns with freezing. However, following some simple winterizing recommendations will assist you in overall better performance, operation and protection during cold weather use.
Envirolet®/SG Low Water Remote Winter Use IMPORTANT Your Envirolet®/SG Low Water Remote System uses water to flush and therefore special care must be taken before using in winter due to concerns with freezing. If you do intend to use your system in the winter or at temperatures below freezing (-0°C/32°F) or close to below freezing, please ensure that all components are heated, well insulated, kept dry and protected to prevent freezing.
Envirolet®/SG FlushSmart VF Winter Use IMPORTANT Your Envirolet®/SG FlushSmart VF System uses water to flush and therefore special care must be taken before using in winter due to concerns with freezing. If you do intend to use your system in the winter or at temperatures below freezing (-0°C/32°F) or close to below freezing, please ensure that all components are heated, well insulated, kept dry and protected to prevent freezing.
Rated Capacity – Maximum Use Each type or model of Envirolet®/SG Composting Toilet Systems has a rated capacity. Do not use above these rated capacities except for brief periods of time. IMPORTANT Any system that will be used above the rated capacity, even for short periods of time, should have an excess liquid drain installed. Look for your system/model below and use within capacity.
• Refer to drain section for proper drain installation. Use as directed. To ensure proper performance, please be sure to contact us if you have installation or operation questions. ENVIROLET®/SG INSTALLATION & OPERATION MANUAL (7MINS11D 12.15) • Envirolet® is a registered trademark. ©2016, Sancor Industries Ltd.
Use & Care – Maintaining Your System Envirolet®/SG Composting Toilet System Use & Care including system start-up, power controls and normal operation instructions. PLEASE READ THIS SECTION CAREFULLY BEFORE USING SYSTEM. WARNING Please follow all safety guidelines when using your Envirolet®/SG Composting Toilet System. IMPORTANT Complete entire system installation before system start-up and use is initiated.
Rated Capacity • • • Your Envirolet®/SG Composting Toilet System has a maximum rated capacity. Do not use above these rated capacities. Refer to Rated Capacity section for list of models and capacities. Operation is Easy • • • • Your Envirolet®/SG Composting Toilet System is easy to operate Please follow all directions for proper performance. Be sure to follow all safety precautions listed in this manual. Refer to Safety Guidelines section for more information.
2. Start of Season: System Start-Up Complete all installation, including venting, draining, etc., before beginning Initial System Start-Up. SYSTEMS THAT REQUIRE EMPTYING START HERE Empty System Ignore this step and begin at step 4 if the system is new and has not yet been used. Typically, you will empty your system at the start of the season. For full-time use or heavier use emptying periods will vary. Refer to Emptying Instructions section for instructions.
AC Electric Systems Envirolet®/SG AC Electric Systems are equipped with a 2-Position toggle power Control Switch that controls the electric components in the Envirolet Works-in-a-Drawer™ Box. Waterless Self-Contained AC Electric models label: Waterless Remote, Low Water Remote and FlushSmart VF AC Electric models label: AC Electric Switch Operation POSITION 2 - SYSTEM IN USE NORMAL OPERATING MODE • • Keep the control toggle switch to Position 2 for normal everyday use.
12VDC Systems Envirolet®/SG 12VDC Systems are equipped with a 2-Position toggle power Control Switch that controls the electric components in the Envirolet Works-in-a-Drawer™ Box. Your 12VDC Battery System will operate in either a powerful dual fan (2) or single fan (1) mode. To conserve energy, your 12VDC Battery System does not use a heater.
• An attached solar power system can provide extended or continuous operation and will keep batteries recharged. OFF - NOT IN USE FOR MORE THAN 4 WEEKS • • For extended periods of non-use (more than 4 weeks) turn system off by disconnecting the battery terminals. It is not advised to use the system with the power off. Even though the Wind Turbine Ventilator will continue to draw air from the system, the static fans can create an impedance in the vent line that will slow evaporation and air flow.
Daily Mix Daily Mix Daily Mix Daily Mix Daily Mix Daily Mix Daily Mix Daily Mix Daily Mix Daily Mix Per Day 1 2 3 4 5 6 7 8 9 10 Per Day ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ Per Day ¼ ½ ¾ 1 1¼ 1½ 1¾ 2 2¼ 2½ *Note about Daily Mix Alternatives • • Our Daily Mix is designed specifically for your system.
and not through the toilet for best results. Use Aerator Bar • Pull the Aerator Bar in and out a few times every week. You can use the Aerator Bar (details below) more often, but please try and use at least every week. Learn more in the Aerator & Rake Bar Operation section. TIP: WET OR DRY • • • If compost appears too wet (or “soupy”) then add and mix more dry additives until compost is dry. If compost appears too dry (or “clay-like”) then spray small amounts of water evenly over compost to moisten.
Refer to Troubleshooting section or contact us for more information if you believe any electric component is not functioning. Check All Air & Liquid Seals • • Inspect that all openings in system are completely sealed for liquid and air. Make sure bottom panel is properly attached and that all areas that silicone-sealed have a proper seal. 9. Aerator & Rake Bar Operation Aerator & Rake Bars Envirolet®/SG Composting Systems are equipped with an Aerator Bar (top bar) and a Rake Bar (bottom bar).
Emptying Instructions Information on when and how to empty your system. IMPORTANT Please use common sense and all normal sanitary precautions when emptying system. Treat your system as you would when cleaning any toilet. Wash hands thoroughly after emptying. INTRODUCTION Emptying the Envirolet®/SG Composting Toilet System is a fast and easy process. Emptying involves using the Rake Bar to empty the composted material down into the soil collection tray.
How to Empty 1. Check System Before emptying, check inside Composting Unit through the toilet seat (Waterless Self-Contained models) or service panel (Waterless Remote, Low Water Remote or FlushSmart VF models) for wetness. Please follow empty wait time recommendations before emptying (discussed in previous section).
3. Emptying Procedure REMOVE SOIL SOLLCTING TRAY Ensure that the soil collecting tray is empty by pulling it out. If Envirolet®/SG has been use recently, liquid may be evident. If so, do not empty at this point and, as directed, let the system “sit” to allow for evaporation. Soil Collecting Tray Removed from Waterless Self-Contained System RE-INSERT SOIL COLLECTING TRAY Push empty Tray back into position so it is ready to collect your compost.
Re-Insert Tray back side of the plastic bottom panel) to ensure it does not have any rips or tears that could cause a leak from your system. Also, be sure to replace soil collecting Tray for next time. This is very important! 6. Re-Attach Bottom Panel With the 2 inner Knobs still attached, but loose, push with your thumbs on the Knobs to bring the plastic Bottom Panel until it comes flush with the Knobs. Place the metal Back Plate downward through the opening in the System.
Troubleshooting ENVIROLET®/SG COMPOSTING TOILET SYSTEM TROUBLESHOOTING Something seem not right with your system? Don’t worry! Please use this troubleshooting guide to help remedy some possible service issues. Check this and then contact us if you require more assistance. • • Topics begin with an introduction explaining the issue and are then followed by the remedies. If you cannot find what you are looking for or require further clarification, please contact us right away.
Issues & Remedies Outside Odour Noticeable odour outside (near or around vent or roof). Poor evaporation Poor evaporation could be occurring due to a liquid build-up issue. Refer to liquid buildup section. Overhanging trees Overhanging trees may affect vent exit air flow. Trim or cut away overhanging trees. High peak roof causing poor evaporation A high roof peak may be inhibiting air flow (wind) to the top of the vent. Raise vent higher. Low Vent Stack The top of your vent stack may be too low (i.
systems use water to flush so there will almost always be some liquid in the system. Improper venting An angled vent can create liquid build-up by not allowing for proper evaporation. A straight vent is best. Never install a 90° bend in the vent. Vent obstruction If anything is in the vent (cob webs, twigs, animals, screens, etc.) it can block it and reduce evaporation. Check and clear vent. Do not place any obstructions in or over the vent, including “screens” (e.g.
Fan Failure Envirolet®/SG AC and DC models have 2 Fans that are essential for proper aeration, evaporation and performance. If one fails, it should be replaced immediately. Fans are mechanical moving parts so they can fail. Vent Fan (left side) failure If you have inside (where Compost Unit is housed) odour, this is an indication that the Vent Fan has failed. Contact dealer or contact customer service help line for replacement instruction. See Fan Replacement.
Aerator or Rake Bar Issues Aerator Bar is difficult to move. This can be caused if the material in the system becomes too dry. Some of the remedies can also be used for Rake Bar issues. Low system use Material may be dry because of low use. Move Aerator Bar (top) back and forth to help break apart the material. Add water (or use toilet) to add moisture. Infrequent use of Aerator Bar Add water (or use toilet) to add moisture. Use Aerator Bar more often.
Water drains from toilet bowl Bowl trap not closed properly. Bowl seal requires cleaning or replacement. Water keeps filling toilet bowl Sand or sediment may be in water supply. Sediment filter required on water supply. Solenoid valve on toilet must be cleaned. Water drains from toilet bowl Bowl trap not closed properly. Bowl seal requires cleaning or replacement. Toilet will not flush. Vacuum Generator not starting. 1.5” flex line blockage. Use wire snake to unblock or replace flex line.
Installation Issues & Errors Installation “errors” can lead to any of the above troubleshooting issues. It is essential that your system be installed correctly for it to perform properly. In this section we will list some possible or common installation errors (or shortcuts) that can lead to later difficulties. Important: Please do not assume that you can “shortcut” proper installation or that a different way is equal to the way outlined in our instructions.