Issues & Remedies
Outside Odour
Noticeable odour outside (near or
around vent or roof).
Poor evaporation
Poor evaporation could be occurring due to a liquid build-up issue. Refer to liquid build-
up section.
Overhanging trees
Overhanging trees may affect vent exit air flow. Trim or cut away overhanging trees.
High peak roof causing poor evaporation
A high roof peak may be inhibiting air flow (wind) to the top of the vent. Raise vent higher.
Low Vent Stack
The top of your vent stack may be too low (i.e., close proximity to sitting area). Raise vent
higher.
Suggested Remedy
You may also want to try, in combination with above remedies, a Sancor™ Air
Solution cartridge.
Inside Odour
Noticeable odour inside location of
Compost Unit (not inside bathroom
where toilet is).
Vent fan not functioning
If the vent fan fails, the blower fan may exhaust air/odour out of unit. Replace vent fan. Refer
to liquid build-up section.
Improper venting
An angled vent can create liquid build-up by not allowing for proper evaporation. A straight
vent is best. Never install a 90° bend in the vent.
Improper sealing of vent connection, Top Panel, Bottom Panel,
drain exits, etc.
Check and re-seal vent connections, Top Panel, Bottom Panel, drain exits. Even a small “pin-
hole” sized opening or leak can cause odour.
Another exhaust fan “competing” with system
Another exhaust fan or vent may be drawing air away from toilet area such as a wood-stove,
open window, ceiling fan, heater etc. Keep composting unit room door and window shut.
8” Flex Drain Not Cut to Size
Be sure that the 8” flex drain (the connection drain from Waterless Toilet to Composting Unit)
on Envirolet®/SG Waterless Remote models does not go from the top of the composting unit
entry point too far down into the tank. It should only extend down about 3-4” maximum from the
entry point. If it is too long it may cause an air-flow issue when waste/compost is above it.
Liquid Build-Up
An unusual accumulation of liquid in
the system. Keep in mind that Low
Water Remote and FlushSmart VF
Electrical problem
Inspect electric WID Box for electric issues or failure. Failed fans or heater can cause liquid to
build-up. Contact customer service, local dealer or correct problem.