CFR2115, CFR2127, CFR2136, CFR2144 Instruction Manual We are here to help! Please contact Customer Service with any questions. Customer Service Americas: 800-359-5520 • 651-484-7988 • info@sanus.com Europe, Middle East, and Africa: + 31 40 2324700 • europe.sanus@milestone.com Asia Pacific: 86 755 8996 9226 • sanus.ap@milestone.com SANUS · 2221 Hwy 36 West · Saint Paul, MN 55113 USA ©2011 Milestone AV Technologies, a Duchossois Group Company. All rights reserved. Sanus is a division of Milestone.
English - How to use this manual Suomi - Oppaan käyttäminen For best results, reference both the text and illustrations. OPT This item is optional English Text Pages 4-17 Saavutat parhaan tuloksen tutustumalla sekä tekstiin että kuviin. Leikkaa katkoviivaa pitkin ja yhdistä kuvat ja suomenkielinen teksti. OPT Tämä vaihtoehto on valinnainen.
6901-002133 <00> 3
English IMPORTANT SAFETY INSTRUCTIONS – SAVE THESE INSTRUCTIONS – PLEASE READ ENTIRE MANUAL PRIOR TO USE Thank you for choosing a Sanus Component Series Rack. The CFR21 series is designed to support audio/video equipment. The total weight capacity for the CFR21 series: CFR2115 226.8 kg (500 lb) CFR2127 340.2 kg (750 lb) CFR2136 385.5 kg (850 lb) CFR2144 453.6 kg (1,000 lb) Each 3U shelf supports up to 36.3 kg (80 lb), each 2U shelf supports up to 22.7 kg (50 lb), and each 1U shelf supports up to 13.
Supplied Parts and Hardware [02] x 2 [03] x 4 [04] x 4 [05] x 16 [01] x 1 [06] 1 Per Shelf CFR2115 3 CFR2127 6 CFR2136 8 CFR2144 9 6901-002133 <00> [07] 2 Per Shelf CFR2115 6 CFR2127 12 CFR2136 16 CFR2144 18 5
1 Install Feet and Casters Install feet [03]. Install Casters [04] using screws [05]. [03] [04] [05] 2 Level Feet Adjust the feet [03] to level the rack. Tighten nuts (N) until they are flush with the bottom of the rack. CAUTION: To avoid potential injury or property damage, always ensure that your rack is level.
3 Remove Cable Access Panels for OPT Cable Management 6901-002133 <00> 7
4 Verify the Grounding Strap has been Installed If the grounding wire has not been installed, install the wire now by attaching one end to the door ground stud, and the other end of the ground wire to the ground stud on the bottom of the rail. 5 Install Fan for Additional Ventilation OPT CAUTION: Avoid damage to your components due to overheating. Make sure that there is adequate space between each unit for proper airflow. Operating temperature inside the rack must not exceed 104°F (40°C).
6 Adjust Shelves and Blanking Panels OPT NOTE: Align the bottom of the shelf or blanking panel (B) with the lines (L) on the rack rail.
7 Adjust Rack Rails OPT Remove the shelves and blanking panels before adjusting the rails. Adjust the top and bottom, and right and left rails evenly. NOTE: For clarity, the front door, top, and side panels are not shown.
8 Load Your Components CAUTION: To prevent tipping, always load the rack from the bottom up, and load the heaviest item in the rack first. 50% of the total weight should be mounted in the lower 1⁄3 of the rack. Rack Shelf Backstops NOTE: rear view with back panels removed. 1. Insert backstop [06] into slot behind component. 2. Slide backstop [06] forward until firmly against component and twist 90 degrees. Component Straps NOTE: side view with panels removed. A.
9 Switch Back Panels OPT To switch the position of the back panels: 1. 1 Remove large upper panel. 2. Remove small lower panel and frame. 3. Fit bottom of large panel into rack frame and angle the panel up until sliding locks snap in place. 4. Flip small panel 180 degrees. 5. Screw panel frame into rack frame and replace small panel.
10 Reverse the Front Door OPT Remove the door 1 1. Remove the door grounding wire from bottom of rack and the door. 2. Turn upper door pin to release from locking tab and pull down to release door from rack and lift door from rack frame. 3. Release upper pin and turn it back to secure it under the locking tab. 4. Remove spacer from bottom door pin. NOTE: Spacer must be used with pin on bottom of door.
10 Reverse the Front Door - continued OPT Flip the door 6 5. Fit spacer onto bottom pin and fit bottom pin into bottom mounting hole in rack. 6. Turn upper pin to release from locking tab and pull down. Fit pin into upper mounting hole in rack. 7. Release pin and turn pin to secure it under locking tab 8. Reattach grounding wire.
10 Reverse the Front Door - continued OPT Flip the door handle 9 Remove screws and bracket. 10 Flip the door handle. 11 Reattach screws and bracket. 12 Loosen the locking cam screw. 13 Flip the locking cam tab to the side nearest the edge of the door. 14 Tighten the locking cam screw.
11 Add Keyed Lock to Door OPT Install keyed lock (purchased separately) in plug hole. Remove plug from side panel. 12 Manage Cables OPT Use tie bars (TB) to bundle cables and wires.
13 Ganging Racks 1 OPT Remove side panels on sides to be connected. Move racks together until sides are touching. 2 IMPORTANT 3 Make sure both racks are level with each other. Fit 4 ganging clips (GC) into frame slots. Press down on clips to secure. IMPORTANT Make sure all 4 ganging clips are fully engaged.
English Suomi Milestone AV Technologies and its affiliated corporations and subsidiaries (collectively, “Milestone”), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions, or variations. Nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind.