INSTALLATION•MAINTENANCE•OPERATION GUIDE WHOLE HOUSE HEPA/UV AIR PURIFIER MODEL S300 HFX HEPA/UV AIR PURIFIER
SAFETY CONSIDERATIONS Installation and servicing or equipment can be hazardous. Only trained and qualified service personnel should install, repair, or service equipment. Untrained personnel can perform basic maintenance functions such as changing lamps. All other operations should be performed by trained service personnel. When working on equipment, observe precautions in the literature, tags and labels attached to the unit or accessory, and other safety precautions that may apply. Follow all safety codes.
Table of contents LIMITED PARTS WARRANTY FIVE-YEAR WARRANTY — This SANUVOX TECHNOLOGIES INC. product is warranted to be free from defects in material and workmanship under normal use and maintenance for a period of 5 years from the date of original installation and for a period of 3 years for the UV Lamp. 1. Getting Started GENERAL INFORMATION 1.1 Unpacking and inspection 1.2 Technical data 3 4 2.
1.2. Technical Data Dimensions and Clearance installation Return Air Plenum Installation Front View Side View - Clearance Side View 4" 97 mm Specifications Model S300HFX Filtration Stage 1 Filtration Stage 2 Weight Plenum Mount Port Openings Collar Mount Port Openings Installation type Electrical Supply Power Consumption Certification Air flow data UV Lamp Prefilter HEPA filter 33 Lbs. 16" x 3.
Installation GUIDE 2. Information for the Installer Special Consideration 2.1 Planning the Installation • Verify clearance on the ductwork to mount the unit using the Forced Air Heating/Cooling system • Respect the Minimum clearance requirements for maintenance and service • Electrical power requirements • Interaction between the HEPA/UV air purifier unit and other mechanical devices. The HEPA/UV air purifier is a versatile appliance with multiple installations configuration.
Installation GUIDE 2.3 Types of Installation: Stand Alone Stand Alone Attic Installation Ideal for homes without a forced air HVAC system. Allows for air filtration and circulation throughout the home. The HEPA system must be operated continuously whenever a part of all the system is located in an unconditioned space below freezing (0ºC, 32ºF) to prevent condensation in the ductwork.
Installation GUIDE 2.4 Installing the unit Tools required Step-by-step Installation • Phillips #2 or Robertson #1 screwdriver • 3/32" drill bit • Tin snips or metal shear • Power drill Steps involved in the preparation of the return plenum mount system: Step 1: Preparing return air plenum Step 2: Preparing ducting flairs Find a location that satisfies both service and maintenance requirements.
Installation GUIDE 2.4 Installing the unit (Continued) Tips to installer Step 2: (Continued) Consult local authorities as to whether the installation of electrical products requires the services of a certified technician or electrician. Cut the four metal tabs to release the mounting flairs for the inlet and outlet ports. Tips to installer Removing the filters from the unit will facilitate the installation. Figure 2.2d Figure 2.
Installation GUIDE 2.4 Installing the unit (Continued) Tips Step 3: Mount Hepa Step 3: (Continued) to installer It is recommended that the filtration unit have a devoted receptacle with 115V. It is not recommended to connect unit with an extension cord. If no receptacle is available please call an electrical contractor to have one installed. Figure 2.3c - Install unit using all supplied fastening hardware.
Installation GUIDE 2.5 UV Lamp Installation Step 1: The UV Lamp is packaged in the filter section of the S300HFX. Remove the UV lamp from the packaging material. The lamp is fragile, use extreme care. Do not touch the glass on the lamp with bare hands. Use the enclosed gloves when handling the lamp. Handle lamp from the ceramic ends. IMPORTANT The Lamp Display LED's are attached to the inside of the front plate. Do not pull the LED's out of the plastic retainers.
Owner’s Operation GUIDE 3. General Operating Information Function Door switch The HEPA/UV air purifier is comprised of a ventilator, speed selection switch, 2 stages of filtration and the cabinet enclosure system. The ventilator pulls air through the prefilter and pushes the same air through the HEPA filter which removes 99.97% of particles that are 0.3µm or larger in size.
Maintenance GUIDE 4. General Maintenance Information When should I service my unit? service and accessories Detailed maintenance information is located on the front decal on motor plate. PRE-FILTER 4.1 Changing Filters After opening the unit’s door, grasp both edges of filter and pull with equal force to slide out the filter. 4.2 Cleaning HEPA FILTER Once a year or as needed, clean the interior of the unit (Wall and motor plates) using mild non-abrasive soap and water.
S300HFX HEPA/UV LIMITED PARTS AND LAMP WARRANTY 5-YEAR WARRANTY — Except for the UV Lamp and Ballast, this SANUVOX TECHNOLOGIES INC. product is warranted to be free from defects in material and workmanship under normal use and maintenance for a period of five years from the date of original installation. A new or remanufactured part to replace the defective part will be provided without charge for the part itself, through a qualified servicing SANUVOX TECHNOLOGIES INC.
NOTES:
NOTES:
1205-REV001 ITEM # 101275 Sanuvox Technologies Inc. 1-888-726-8869 Email: info@sanuvox.com www.sanuvox.