Manual

OPERATION
IMPORTANT: When the Sanuvox SR+ is turned on by pressing the POWER button, the RED LED on the POWER button will
illuminate and the status LED will flash in alternate colors singling the SR+ is warming-up. The warm-up will last approximately 45
seconds, after which time the unit will enter ‘STANDBY-MODE’. THE UNIT WILL NOT FUNCTION UNTIL THE WARM-UP IS
COMPLETE.
1. Once the SR+ is in ‘STAND-BY’ mode, the unit will be waiting for airflow in order for the UV Lamp to turn ON. The SR+ has a built-in
Thermistor that controls operation. When there is airflow the Thermistor changes temperature causing the SR+ Lamp to come on. When
airflow stops, the SR+ UV Lamp will turn OFF accordingly.
2. When in ‘STAND-BY’ and there is airflow, the SR+ UV Lamp will come ON and the LED will illuminate GREEN.
3. When there is no airflow, the status LED will be OFF and the RED POWER Button LED will remain ON.
SR+
INSTALLATION
MANUAL
PLEASE SAVE FOR YOUR RECORDS
Serial Number#
Date Installed:
Installed By:
Installers Contact info.:
SANUVOX TECHNOLOGIES INC. © 2013
Follow all safety codes.
Wear safety glasses and work gloves.
1-888-SANUVOX www.sanuvox.com
Before installing or performing maintenance or
service on the purifier, turn off unit and disconnect
from power source. Electrical shock can cause
injury or death. There may be more than one
disconnect switch.
Never expose eyes or skin to ultraviolet light from
any source. The Purifier MUST be DISCONNECTED
from power source before performing maintenance
or service. Personal injury may result.
Do not touch Lamp glass without gloves. Reduced
performance of Lamp may result. Clean Lamp after
handling.
Use only specified replacement Lamps with you
Purifier. Use of an incorrect Lamp can result in
damage to the Purifier and/or Lamp.
WARNING
WARNING
WARNING
The UV Lamp contains a small quantity of mercury.
If a Lamp breaks, clean and dispose of with care.
WARNING
WARNING
UNDERSTANDING THE LED STATUS DISPLAY
Troubleshooting the UV Lamp
To check to make sure the UV Lamp has in fact failed:
UV LAMP RESET BUTTON (To be used to reset “Days Left” after UV Lamp change-out)
Disconnect the plug from the Lamp.
Placing the probe of the ohmmeter to one of the four pins on the end of the Lamp, touch the other probe of the ohmmeter to each of the other pins
until you find the matching pin. The ohmmeter shows continuity (closed circuit). This indicates that the filament is good. Check the other two pins. If
both sets of filaments test OK (continuity), the Lamp is functioning. If one or both sets of filaments read an open circuit (no continuity) on resistance,
the Lamp must be replaced.
To the bottom right of the SR+ cover right you will see a small REST hole. To RESET the UV Lamp Replacement LED Reminder back to 3 years,
insert a small object similar to a paper clip into the hole holding down the button for 3 seconds.
04/13 V.4
1-888-SANUVOX www.sanuvox.com
LED Solid GREEN = SR+ is ON with UV Lamp ON sensing airflow
LED Flashing GREEN = Warm up sequence lasting up to 45 seconds
LED Flashing ORANGE = UV Lamp has functioned for 3 years and is due for replacement.
LED Solid RED = UV Lamp has FAILED. Must be replaced
LED Alternating RED+GREEN = Thermistor Issue
LED OFF = Unit is on Stand-by (provided RED power button LED is illuminated)
NOTE: The only time the RED Power button LED will be OFF is if power is interrupted to the
unit or the Power Button is in the OFF position.