EXZES ZZ Radio System Manual
91
TR
EXZES ZZ
2.4GHZ FH4T RADIO CONTROL SYSTEM USER'S GUIDE
Telemetry System with Sanwa Synchronized Link Support
Changing the Stroke Percentage Value:
The Stroke percentage value determines the amount of Brake that's applied automatically when the Anti-Lock Braking function is
turned ON. A Stroke percentage value of 1% or greater must be programmed for the Anti-Lock Braking function work. If a Stroke
value of OFF is chosen, the Anti-Lock Braking function will not work.
1) FromwithintheRACINGmenu,scrollUPorDOWNtohighlighttheALBmenu.
STROKEsettingrangeisOFFto100%.ThedefaultsettingisOFF.
2) PresstheENTERkeytoopentheALBmenu.STROKE>OFFwillbehighlighted.
3) PresstheENTERkey,thenscrollUPorDOWNtochoosethedesiredStroke
percentage value. Increasing the Stroke percentage value will Increase Throttle
servo travel in the Brake direction and Decreasing the Stroke percentage
value will Decrease Throttle servo travel in the Brake direction.
ALB MENU
{
ANTI-LOCK BRAKING
}
RACING
Changing the Point Percentage Value:
The Point percentage value determines the position along the length of Brake Side servo travel that the Anti-Lock Braking function
Activates at when turned ON. For example, if set to 80%, you will have Normal Braking from the Throttle Neutral Point to 79% of
servo travel. At 80% of servo travel and beyond, the Anti-Lock Braking function will Activate when turned ON.
POINT setting range is 5% to 100%. The default setting is 80%.
1) FromwithintheALBmenu,scrollUPorDOWNtohighlightPOINT>80%.
2) Press theENTERkey,thenscroll UP or DOWNtochoosethedesired Point
percentage value. Increasing the Point percentage value will cause the
Anti-Lock Braking function to Activate later and Decreasing the Point percentage
value will cause the Anti-Lock Braking function to Activate sooner.
Changing the Release and Hold Values:
The Release and Hold values determine the speed at which the Brake pulsates. By changing the Release and Hold values, you
can make the Brake pulsate Faster or Slower. The Release value determines how quickly the Brake moves from the Point setting
to the Stroke setting and the Hold value determines how quickly the Brake moves from the Stroke setting back to the Point setting.
We recommend using equal Release and Hold values, although different values can be used to fine-tune how the Brake
pulsates.UsingLowervaluesmaketheBrakepulsateFasterandusingHighervaluesmaketheBrakepulsateSlower.
RELEASE setting range is 0.01s to 1.00s. The default setting is 0.03s.
1) FromwithintheALBmenu,scrollUPorDOWNtohighlightRELEASE>0.03s.
2) Press theENTER key, thenscroll UP orDOWN to choosethe desired Release
value in Seconds. Increasing the Release value will cause the Brake to move from
the Point setting to the Stroke setting Slower and Decreasing the Release value
will cause the Brake to move from the Point setting to the Stroke setting Faster.
HOLD setting range is 0.01s to 1.00s. The default setting is 0.03s.
3) FromwithintheALBmenu,scrollUPorDOWNtohighlightHOLD>0.03s.
4) Pressthe ENTERkey, thenscroll UPor DOWNto choosethe desiredHold
value in Seconds. Increasing the Hold value will cause the Brake to move
from the Stroke setting back to the Point setting Slower and Decreasing the
Hold value will cause the Brake to move from the Stroke setting back to the
Point setting Faster.
RACING