Datasheet

19
(Pa)(inch H
2
O)
(CFM)
(m
3
/min)
静圧
風量
0
0.05
0.10
0.15
0.20
0 1 2 3 4 5 6 7
4.5 V
5.5 V
5 V
0
10
0.05 0.10
20
30
40
50
0.15 0.20
(Pa)(inch H
2
O)
(CFM)
(m
3
/min)
静圧
風量
0
0.05
0.10
0.15
0.20
0 1 2 3 4 5 6 7
30
0
0.05
10
20
60
40
50
0.10 0.15 0.20
4.5 V
5.5 V
5 V
(Pa)(inch H
2
O)
(CFM)
(m
3
/min)
静圧
風量
0
0.05
0.10
0.15
0.20
0.25
0 1 2 3 4 5 6 7
0
0.05
10
0.10 0.15
0.20
12 V
7 V
13.8 V
40
30
20
50
60
DC
DC Fan 40 mm sq.
Model no.
Rated voltage
Operating voltage range
Rated current
Rated input Rated speed Max. airow
Max. static pressure
SPL
Operating temperature
Expected iife
[V] [V] [A] [W] [min
-1
]
[m³/min]
[CFM] [Pa] [inchH
²
O] [dB (A)] [˚C] [h]
109P0405H901
5 4.5 to 5.5
0.16 0.8 6200 0.15 5.3 41.2 0.165 25
-10 to +60
40000/60˚C
109P0405M901
0.11 0.55 5000 0.12 4.2 27 0.108 21
109P0412H901
12 7 to 13.8
0.07 0.84 6200 0.15 5.3 41.2 0.165 25
109P0412M901
0.06 0.72 5000 0.12 4.2 27 0.108 21
The following sensor and control options are available for selection.
Available for all models.
Without sensor
Lock sensor
Differs according to the model. Refer to the table on pp. 562 to 563.
PWM control
Static pressure
Static pressure
Airow
Static pressure
Airow Airow
DC Fan
40
×
40
×
10 mm
San Ace 40 9P type
General Specications
Material ………………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1)
Expected life …………………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C,
rated voltage)
Motor protection function ………………… Locked rotor burnout protection, Reverse polarity protection
For details, please refer to p. 547.
Dielectric strength …………………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
Insulation resistance ………………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
Sound pressure level (SPL) ……………… At 1 m away from the air inlet
Storage temperature ……………………… -30 to +70˚C (Non-condensing)
Lead wire ……………………………………… Red Black or Blue
Sensor
Yellow
Mass ……………………………………………… 19 g
Specications
The models listed below
have ribs and pulse sensors.
Operating voltage range Operating voltage range Operating voltage range
Airow - Static Pressure Characteristics
109P0405H901 With pulse sensor
109P0405M901 With pulse sensor
109P0412H901 With pulse sensor

Summary of content (2 pages)