Datasheet

30
(Pa)
(inch H
2
O)
(CFM)
(m
3
/min)
静圧
風量
0 2 4 6 8 10
0
0.1
0
90
80
70
60
50
40
30
20
10
0.2 0.3
0
0.05
0.10
0.15
0.20
0.25
0.30
0.35
5.5 V
5 V
4.5 V
(Pa)(inch H
2
O)
(CFM)
(m
3
/min)
静圧
風量
0 2 4 6 8 10
0
0.1
0
20
40
60
0.2 0.3
0.25
0.20
0.15
0.10
0.05
5.5 V
5 V
4.5 V
0
0.1 0.2 0.3
10
20
30
40
50
60
70
80
90
100
0 2 4 6 8 10 12 14
0
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
4.5 V
5.5 V
0.4
0.50
110
120
130
(Pa)(inch H
2
O)
静圧
風量
(CFM)
(m
3
/min)
5 V
Model no.
Rated voltage
Operating voltage range
Rated current
Rated input Rated speed Max. airow
Max. static pressure
SPL
Operating temperature
Expected life
[V] [V] [A] [W] [min
-1
]
[m³/min]
[CFM] [Pa] [inchH
²
O] [dB (A)] [˚C] [h]
109P0405J601
5 4.5 to 5.5
0.46 2.3 9800 0.28 9.9 98.5 0.396 39
-20 to +70
40000/60˚C
109P0405H601
0.32 1.6 8000 0.225 8.0 65.7 0.264 33
109P0405F601
0.25 1.25 6500 0.183 6.5 45.1 0.181 28
60000/60˚C
109P0405M601
0.12 0.6 5000 0.136 4.8 26.5 0.106 24
109P0412G601
12
7 to 13.8
0.28 3.36 12500 0.35 12.4 153.8 0.618 44
-20 to +60
40000/60˚C
109P0412D601
0.18 2.16 11000 0.31 10.9 124 0.498 42
60000/60˚C
109P0412E601
0.13 1.56 9200 0.26 9.2 87.3 0.351 37
-20 to +70
109P0412H601
0.11 1.32 8000 0.225 8.0 65.7 0.264 33
109P0412F601
0.09 1.08 6500 0.183 6.5 45.1 0.181 28
109P0412M601
8 to 13.8 0.06 0.72 5000 0.136 4.8 26.5 0.106 24
109P0424G601
24
12 to 27.6 0.15 3.6 12500 0.35 12.4 153.8 0.618 44
-20 to +60
40000/60˚C
109P0424D601
12 to 27.6 0.13 3.12 11000 0.31 10.9 124 0.498 42
109P0424H601
12 to 27.6 0.07 1.68 8300 0.233 8.2 69.6 0.28 35
-20 to +70
60000/60˚C
109P0424F601
14 to 27.6 0.06 1.44 6500 0.183 6.5 45.1 0.181 28
109P0424B601
20.4 to 27.6 0.06 1.44 5200 0.14 4.9 28.3 0.114 25
The following sensor and control options are available for selection.
Available for all models.
Without sensor
Differs according to the model. Refer to the table on pp. 562 to 563.
Lock sensor
DC Fan
40
×
40
×
20 mm
San Ace 40 9P type
General Specications
Material ………………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1)
Expected life …………………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C,
rated voltage)
Motor protection function ………………… Locked rotor burnout protection, Reverse polarity protection
For details, please refer to p. 547.
Dielectric strength …………………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
Insulation resistance ………………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
Sound pressure level (SPL) ……………… At 1 m away from the air inlet
Storage temperature ……………………… -30 to +70˚C (Non-condensing)
Lead wire ……………………………………… Red Black or Blue
Sensor
Yellow
Mass ……………………………………………… 45 g
Specications
The models listed below have ribs and pulse sensors.
Operating voltage range Operating voltage range Operating voltage range
Airow - Static Pressure Characteristics
109P0405J601 With pulse sensor
109P0405H601 With pulse sensor
109P0405F601 With pulse sensor
Static pressure
Static pressure
Static pressure
Airow
Airow
Airow

Summary of content (3 pages)