Datasheet

3-33-1, Minami-Otsuka, Toshima-ku, Tokyo, 170-8451, Japan TEL: +81 3 5927 1020 http://www.sanyodenki.com
The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies.
“San Ace” is a trademark of SANYO DENKI CO.,LTD.
Specifications are subject to change without notice.
The products shown in this catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited.
To protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion.
Notice
CATALOG No. C1032B001 ‘13.12
Option
10.5±0.5
4-
φ11±0.5
124
±
1
104.8
±
0.3
124±1
104.8
±0.3
4-
φ4.3±0.3
4-2±0.5
Resin filter kits
Model: 109-1000F13 (13PPI), 109-1000F20 (20PPI), 109-1000F30 (30PPI), 109-1000F40 (40PPI)
Plug cord
Model: 489-1635-L10, 489-1635-L21
φ
42.
2
φ1.6
φ1.6
φ
113
φ
148
130
152.5
1.5
0.5
5
1
0
4.3±
0.3
Outlet side
152.5
±
0.5
5
1
0
φ
113
4.3±0.3
φ18.6
130
φ
148
Inlet side, Outlet side
φ1.6
φ1.6
Finger guards
Model: 109-019C Surface treatment: Nickel-chrome plating (silver)
: 109-019H
 
: Cation electropainting (black)
Color
Model: 109-019E Surface treatment: Nickel-chrome plating (silver)
: 109-019K
 
: Cation electropainting (black)
Color
Model
L
10
L
21
Power cord length (mm)
1,000
2,100
Wiring harness for sensor
Model: 489-1636
Pre-soldered
1000
±20
10
±1
Pre-soldered
50
±
5
10
±
2
L
20
4
17
10
15.5
8
10
8
4
Common Specifications
Material ・・・・・・・・・・・・・・・・・・・・・・・・・・
Expected Life ・・・・・・・・・・・・・・・・・・・・・
Motor Protection System ・・・・・・・・・・
Dielectric Strength ・・・・・・・・・・・・・・・・
Sound Pressure Level (SPL) ・・・・・・・・
Operating Temperature ・・・・・・・・・・・・
Storage Temperature ・・・・・・・・・・・・・・
Mass ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
Frame: Plastics (Flammability: UL94V-0), Impeller: Plastics (Flammability: UL94V-1)
Refer to specifications
(L10: Survival rate: 90% at 60 , rated voltage, and continuously run in a free air state)
Burnout protection at locked rotor condition
50/60 Hz, 1,500 VAC, 1 minute
(between power terminal and frame or between lead conductor and frame)
Expressed as the value at 1 m from air inlet side
Refer to specifications (Non-condensing)
30 to 75 (Non-condensing)
Approx. 290 g
120×120×38mm
[
m
3
/min
] [
CFM
] [
Pa
] [
inchH2O
]
Model No.
Rated Voltage
[V]
Operating
Voltage Range
[V]
Rated Current
[A]
Frequency
(Note)
[Hz]
Rated Input
[W]
Max. Air Flow
Max.
Static Pressure
SPL
[
dB(A)]
Operating
Temperature
[]
Expected Life
[h]
Rated Speed
min
-1
0.089AD1201H12 4.4 3,250 3.0 106 84 0.34 42100 to 240 90 to 264 20 to 75
60,000
50/60
Note: 50/60 Hz compatible.
Available options:
Pulse Sensor Lock Sensor
Low Speed Sensor
Please contact us for details on the following specifications:
Specifications
The model no. below has ribs and no sensors. For models without ribs, append "1" to the model no.
(Ribless model depicted)
Features
Low Power Consumption
Power consumption is reduced by approximately 72%
compared with our conventional AC fan.
*
Long Life
The San Ace 120AD has an expected life of 60,000 hours
(approximately 6 years), approximately 2.4 times that of our
conventional AC fan.
*
Wide Range
A rated voltage range of 100 to 240 VAC allows for usage in
both 100 VAC and 200 VAC systems. Rotation speed remains
constant even at different input voltages.
* Our conventional AC fan is 120 x 120 x 38 mm San Ace 120,
Model No. 109S072UL at a frequency of 60 Hz.