INSTRUCTION MANUAL FIRST MADE FOR SA-76P, SA-96P,SA-126P & SA-186P MATERIAL OR MODEL *PAPER-JO DIMENSION OR MAKER WOODFREE 80gm COLOR BLACK Print NOTE A4 SIZE APPROVALS N.Yamazaki 2005/Sep/18 CHECK Tai C. S 2005/Sep/08 DESIGN Tai C. S 2005/Sep/08 Andy .P 28/Feb/08 C TAI C S 28/Feb/08 1.) Warranty Card Back. 3 Andy .P 18/Aug/06 B TAI C S 15/Aug/06 1.) Text changed : Cover & Pg 2 rated value 2 K. Fujinaka 18/Dec/05 A TAI C S 15/Dec/05 APPROVALS DRAWN DATE 1.
INSTRUCTION MANUAL ( With Warranty Card ) Cooling only Model SA-76P SA-96P SA-126P SA-186P Room Air Conditioner Save These Instructions! P ub. OI-85164119749003 © S ANYO 2006 SANYO Electric Co., Ltd.
Thank you for choosing SANYO air conditioner. Our design is based on the best efficiency and the lowest noise operation and it can keep the room comfortable. Please read this Instruction Manual carefully before operating the unit and keep it for consultation. If you still have any difficulties or problems, consult your dealer for help.
Function and working temperature range Introduction Window type room air conditioners of SANYO can regulate the room temperature,dry the room. It is convenient for your work,study and life. It can be widely used in residence, shop, hotel, office, library and laboratory, and so on. Cooling in summer Exchange fresh air Open storm door to keep the fresh air in the room. In hot summer, Air conditioner can cool down room air by transferring heat out.
Technical specifications Table 1 Model Function SA-76P SA-96P SA-126P SA-186P Cooling Cooling Cooling Cooling 230 V~ 60Hz Power supply Cooling capacity (KJ/h) 7,400 9,300 12,600 18,200 Power input (kW) 0.72 0.90 1.33 1.95 Current (A) 3.3 4.2 5.9 8.5 Refrigerant R22 (g) 500 620 720 710 (KJ/Wh) 10.3 10.3 9.5 9.3 Indoor (Hi / Low) 48 / 45 49 / 43 50 / 46 52 / 47 Outdoor (Hi / Low) 56 / 52 56 / 52 58 / 54 59 / 53 560 × 375 × 600 660 × 428 × 770 48 65 E.E.
Operating condition Please operate air conditioner in correct conditions as following: Cool mode operation 1. Outdoor temperature should be in range of 19 for air conditioner to breakdown. 2. Room temperature should be in the range of 19 to 43 . Otherwise it is possible to 32 . 3. Room humidity should be lower than 90%, Otherwise it is possible to dew at air conditioner surface and even drop water.
Installation Installation precaution: Window type conditioner is so valuable and the improper installation of it will cause a lot of damage! Please associate the professional technician to install the unit and don’ t install it by yourself. Otherwise, we are not responsible for the damage like this. Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the name plate. Location: The condensation water must be drained away conveniently.
Installation procedure: Horizontal line 1) Remove the sticker from the front panel. 2) Put the unit into the installation hole. When installing the unit, it should be slanted down to the back to avoid the enlargement of noise or vibration. (Slant between 6-10mm.) (Shown at right figure.) The installation place should be strong enough to avoid the enlargement of noise or vibration. 3) Fill up sews in the cabinet with sponge or foam.
Inside View Exterior V iew Inside V iew Screw Drainage Pan Exterior View Bottom Side View of Drainage Pan Remove the rubber plug Screw Drainage Pan Bottom Side V iew of Drainage Pan Note: Drain hose or tubing can be purchased locally to satisfy your particular needs. The drainage pipe shall be steadily connected with the drainage faucet without leakage. Notes for installation Remove Before removing air conditioner to the other place, you should contact the seller firstly.
Part identification Air direction adjustment Vertical airflow direction vane (Airflow direction adjustment up and down). The vertical airflow direction vane is controlled by positioning the vane to discharge the air upwards, downwards or straight out.
Low fan speed with cooling operation 8
Air conditioner operation FAN Mode, 9 7
Operation tips Operation for comfort and economy Do not overcool the room Keep blind or curtains closed, Adjust the vertical and temperature, this is not good for health and waste electricity. Do not let sunshine enter the room directly when the air conditioner is in operation. horizontal airflow direction to ensure a uniform temperature Clean the air filter regularly. Blackages in the air filter reduce dehumidifying effects. Clean at least once every two weeks. Ventilate the room occasionally.
Caution 1) T he plug must be accessible after the appliance is positioned. 2) Do not use this appliance in the laundry. 3) If the power cord is damaged, it must be replaced by the manufacture or its service agent in void of hazard. Do not pull out the power cord. Damage to the cord may result in serious electrical shocks. Do not use the air conditioner for other purposes such as drying clothes, preserving foods, keeping animals, or cultivating vegetables. Do not block the air intake and outlet vents.
Care and maintenance Always turn off the air conditioner and main power supply before cleaning to ensure safety. Clean unit Air filter 1. Plug out first before cleaning. The air filter behind the intake grille should be washed at least every two weeks or as often as it needs cleaning. Plug out only after air conditioner stops at all. How to clean the air filter: 1. To remove the air intake grille, grasp the tab on the filter and pull to take out. 2.
When trouble shooting If your air conditioner does not work properly, first check the following items before ask for servicing, it help to save your time and money. If it still does not work properly, then only contact your dealer or service center. Fault phenomenon Trouble-shooting * Is power fail? * Is plug out? * Is power fuse or switch off? * Is voltage higher than 253V or lower than 207V? Air conditioner does not operate at all.
Immediately stop all operations and plug out, contact with your dealer in the following situations. * Operation starts or stops abnormally; * Power fuse or switch often breaks; * Carelessly splash water or something into air conditioner; * Electrical lines are much hot or lines cover breaks; * Other strange situations.
WARRANTY CARD WARRANTY REGISTRATION ! ! ! Serial No. Air Conditioner Model !Invoice No. Date of Purchase Dealer (Name) (Address) Customer's Name and Address IMPORTANT TO VALIDATE YOUR ONE (1) YEAR WARRANTY COMPLETE AND MAIL THIS CARD WITHIN 10 DAYS. DETACH AND RETAIN THIS PORTION - RETURN ABOVE 1 Year Warranty Air Conditioner Serial No.
SANYO Service Corporation Basement, SolidHouse Building 2285 Don Chino Roces, Avenue, Ext. Makati City, Philippines Tel. No.: (632) 892-1493 Telefax No.: (632) 892-1260 Website: www.sanyo.com.ph Note: Please encircle clearly the address of the nearest service center at your area. QUEZON CITY Branch 137-A Roosevelt Ave., SFDM Quezon City Tel No.: (02) 374-1349, 414-9647 DAGUPAN Branch No. 3 Pinkies Bldg., Zamora cor. Gomez St., Dagupan City, Pangasinan Tel / Fax No.